C1645M-A (9/06) 21
Figure 10. RS-422 Data Communication Wiring
RS-422
DATA SELECTION
RS-422 DATA CONNECTIONS BETWEEN DEVICE A AND FR85041 RECEIVER
1 TX+
2 TX-
3 RX+
4 RX-
(DATA OUT+)
(DATA OUT-)
(DATA IN+)
(DATA IN-)
TX+
TX-
RX+
RX-
(DATA OUT+)
(DATA OUT-)
(DATA IN+)
(DATA IN-)
5
6
7
8
GND
RX+
RX-
TX+
TX-
FT85041
TRANSMITTER –
DATA CONNECTOR
RS-422
DATA SELECTION
RS-422 DATA CONNECTIONS BETWEEN DEVICE B AND FT85041 TRANSMITTER
DEVICE B
RS-422
DEVICE A
FR85041
RECEIVER –
DATA CONNECTOR
1
2
3
4
5
6
7
8
GND
RX+
RX-
TX+
TX-