Panasonic EX-10 Series Smoke Alarm User Manual


 
233
EX-10
All models
SENSING CHARACTERISTICS (TYPICAL)
Correlation between setting distance and excess gain
0 200
7.874
600
23.622
800
31.496
1,000
39.370
1
10
5
100
400
15.748
Excess gain
50
EX-13
EX-17
EX-11
EX-15
Setting distance L (mm in)
01
3.281
3
9.843
4
13.123
5
16.404
1
10
5
100
2
6.562
Excess gain
50
Setting distance L (m ft)
EX-19
Thru-beam type
EX-19
Parallel deviation Angular deviation
Parallel deviation with slit masks ("1.2 mm "0.047 in) Parallel deviation with slit masks ("1.5 mm "0.059 in)
Thru-beam type
200
7.874
100
3.937
0 100
3.937
200
7.874
0
500
19.685
1,000
39.370
Receiver
Emitter
L
#
Setting distance L (mm in)
Left
Right
Center
Operating point ?(mm in)
40 20 0 20 40
0
500
19.685
1,000
39.370
L
$
Receiver
Emitter
Setting distance L (mm in)
Left
Right
Center
Operating angle
$
( Њ )
EX-11EX-11E
EX-15EX-15E
Parallel deviation Angular deviation
Thru-beam type
Receiver
Emitter
Receiver
100
3.937
50
1.969
050
1.969
100
3.937
0
Left
Right
Center
Operating point ?(mm in)
200
7.874
100
3.937
150
5.906
EX-11
EX-15
EX-11
EX-15
EX-11E
EX-15E
EX-11E
EX-15E
L
#
L
#
Setting distance L (mm in)
Emitter
50
1.969
Emitter
Receiver
Emitter
Receiver
20 10 0 10 20
0
50
1.969
100
3.937
150
5.906
200
7.874
Left
Right
Center
Operating angle
$
( ° )
EX-11
EX-15
EX-11
EX-15
EX-11E
EX-15E
L
$
L
$
Setting distance L (mm in)
EX-11E
EX-15E
200
7.874
100
3.937
0 100
3.937
200
7.874
0
200
7.874
400
15.748
600
23.622
800
31.496
Slit on one side
Slit on both sides
Receiver
Emitter
L
#
Setting distance L (mm in)
Left
Right
Center
Operating point ?(mm in)
200
7.874
100
3.937
0 100
3.937
200
7.874
0
500
19.685
1,000
39.370
Slit on one side
Slit on both sides
Receiver
Emitter
L
#
Setting distance L (mm in)
Left
Right
Center
Operating point ?(mm in)
EX-13EX-13E
EX-17EX-17E
Parallel deviation Angular deviation
Parallel deviation with slit masks ("1.2 mm "0.047 in) Parallel deviation with slit masks ("1.5 mm "0.059 in)
Thru-beam type
40
1.575
20
0.787
020
0.787
40
1.575
0
EX-13/17
Slit on one side
Receiver
Emitter
L
#
400
15.748
300
11.811
200
7.874
100
3.937
EX-13/17
Slit on both sides
EX-13E
/
17E
Slit on one side
EX-13E/17E
Slit on
both sides
Setting distance L (mm in)
Left
Right
Center
Operating point ?(mm in)
100
3.937
50
1.969
050
1.969
100
3.937
0
Slit on one side
or both sides
Slit on one side,
sensing range: 350 mm 13.78 in
Slit on both sides,
sensing range: 300 mm 11.81 in
Receiver
Emitter
L
#
400
15.748
300
11.811
200
7.874
100
3.937
Setting distance L (mm in)
Left
Right
Center
Operating point ?(mm in)
Emitter
Receiver
Emitter
Receiver
100
3.937
50
1.969
050
1.969
100
3.937
0
Left
Right
Center
Operating point ?(mm in)
200
7.874
400
15.748
600
23.622
800
31.496
EX-13
EX-17
EX-13
EX-17
EX-13E
EX-17E
EX-13E
EX-17E
L
#
L
#
Setting distance L (mm in)
Emitter
Receiver
Receiver
20 10 0 10 20
Left
Right
Center
Operating angle
$
( ° )
EX-13
EX-17
L
$
L
$
Emitter
EX-13
EX-17
0
200
7.874
400
15.748
600
23.622
800
31.496
EX-13E
EX-17E
EX-13E
EX-17E
Setting distance L (mm in)
08/2005