AIR PRESSURE SWITCH
Fig. 46
BLUE
BLACK
BLACK
1
2
BLACK
DL 1E
BROWN
BLUE
3
3
1
1
2
KROMSCHRODER
HUBA 605
2
1
3
BROWN
BLUE
3
BROWN
KROMSCHRODER
HUBA 602
1
2
2
3
HUBA 605
HUBA 602
23
1
P1
P2
Plate
2 fixing screw
2 fixing screw
White silicone
Red silicone tube
Fig. 45
Over ride
By pressing the over ride button (E) the timer programme is over ridden ie, if programme is in OFF time it will
come ON and if in ON time will go OFF.
The timer will revert back to it set programme on reaching the next ON or OFF time.
When the programme is on over ride the sign will be shown in the display window (B).
Reset Button
By the use of a pencil the reset button can be pushed (R). This will clear all programmes apart from those
factory pre set.
Reset is only possible with switch (A) in set Clock position!