J SERIES C ONNECTION TYPES
The following charts show the response time of combinations of a
Master Unit and a Slave Unit, and then they show combinations
of a S lave Unit connected in series. For example, the response
time of the combination of F3S-BM122P30 and F3S-BS302 is
30 ms.
Master unit
Response Time per Slave Unit F3S-
BS122 BS182 BS242 BS302
F3S-BM122Pjj 20 ms 23 ms 27 ms 30 ms
F3S-BM182Pjj 23 ms 27 ms 30 ms 34 ms
F3S-BM242Pjj 27 ms 30 ms 34 ms 37 ms
F3S-BM302Pjj 30 ms 34 ms 37 ms 41 ms
F3S-BM362Pjj 34 ms 37 ms 41 ms 45 ms
F3S-BM422Pjj 37 ms 41 ms 45 ms 49 ms
F3S-BM482Pjj 41 ms 45 ms 49 ms 54 ms
F3S-BM542Pjj 45 ms 49 ms 54 ms 57 ms
F3S-BM602Pjj 49 ms 54 ms 57 ms 61 ms
F3S-BM662Pjj 54 ms 57 ms 61 ms 65 ms
Master Unit Response Time per Slave Unit F3S-
U
BS047 BS067 BS087 BS107
F3S-BM047Pjj 20 20 20 20
F3S-BM067Pjj 20 20 20 20
F3S-BM087Pjj 20 20 20 20
F3S-BM107Pjj 20 20 20 20
F3S-BM127Pjj 20 20 20 21
F3S-BM147Pjj 20 20 21 23
F3S-BM167Pjj 20 21 23 24
F3S-BM187Pjj 21 23 24 25
F3S-BM207Pjj 23 24 25 26
F3S-BM227Pjj 24 25 26 27
Master Unit Response Time per Slave Unit F3S-
U
BS065 BS095 BS125 BS155
F3S-BM065Pjj 20 20 20 21
F3S-BM095Pjj 20 20 21 22
F3S-BM125Pjj 20 21 22 24
F3S-BM155Pjj 21 22 24 26
F3S-BM185Pjj 22 24 26 28
F3S-BM215Pjj 24 26 28 30
F3S-BM245Pjj 26 28 30 32
F3S-BM275Pjj 28 30 32 34
F3S-BM305Pjj 30 32 34 35
F3S-BM335Pjj 32 34 35 37