NuTone CV352 Vacuum Cleaner User Manual


 
DIMENSIONAL CHART
MODEL
DIMENSION CV-352
A 27"
B7
3
4
"
C6
1
2
"
D13
5
8
"
7
POWER UNIT INSTALLATION
MOUNTING See Figure 18.
1. Locate the power unit within six feet of a grounded electrical
outlet.
2. Drill
3
16" diameter pilot holes for the two (2) mounting screws in a
wall stud or strong support. See Figure 19.
3. Tighten mounting screws. Leave approximately
1
8" to
3
16"
clearance between head of screw and wall.
4. Hang power unit onto mounting bolts. Make sure top keyhole
slot and lower slot in mounting bracket are engaged behind
mounting screws. Pull down to secure.
5. Remove dirt canister from power unit.
6. Install soil bag and securely replace dirt canister.
NOTE: Cyclonic model does not use a soil bag.
TUBING CONNECTIONS
1. Using rubber couplings and hose clamps, connect intake and
exhaust tubing to the power unit.
2. Connect intake tubing to lower intake tube on power unit.
3. Connect exhaust tubing to upper exhaust tube on the power unit.
4. Make sure all tubing connections are air tight.
5. The exhaust should not be vented into a wall, a ceiling or a
concealed space in the house. The exhaust line should be
terminated outside the home, using Model 393 Wall Cap or a
roof vent.
WIRING See Figure 20.
Grounding Instructions – This appliance must be grounded. If
it should malfunction or breakdown, grounding provides a path of
least resistance for electric current to reduce the risk of electric
shock. This appliance is equipped with a cord having an
equipment-grounding conductor and grounding plug. The plug
must be plugged into an appropriate outlet that is properly installed
and grounded in accordance with all local codes and ordinances.
Danger – Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or service person if you are in doubt as whether
the outlet is properly grounded. Do not modify the plug provided
with the appliance – if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
This appliance is for use on a nominal 120-volt circuit and has a
grounding plug. Make sure that the appliance is connected to an
outlet having the same configuration as the plug. No adapter
should be used with this appliance.
1. Connect low voltage wire (18 gauge, 2-conductor, Model 376) to
two low voltage wires located on outside of the power unit.
2. The power unit is equipped with a six foot grounded cord. Plug
cord into 120 volt grounded receptacle.
12"
18"
“D”
“B” TOP
MOUNT
BOLT
“A”
OVERALL
HEIGHT
18" MINIMUM
ABOVE FLOOR
12" MINIMUM TO CEILING
FRONT VIEW
INTAKE
EXHAUST
“C”
INTAKE
EXHAUST
TOP VIEW
MINIMUM WALL CLEARANCE DIMENSIONS
FIGURE 18
TOP OF POWER UNIT
TOP
KEYHOLE SLOT
MOUNTING
BRACKET
LOWER
SLOT
11
1
/2"
FIGURE 19
INLET
INLET INLET
NOTE: POWER UNIT
CONTROL LEADS ARE
TO BE CONNECTED TO
INLET LEADS WITH
SUITABLE WIRE
CONNECTORS.
WIRING
120vAC ELECTRICAL
OUTLET
MODEL 376 (18/2) WIRE
TO
OTHER
INLETS
INLET
LEADS
POWER
UNIT
POWER UNIT
CONTROL LEADS
POWER CORD
FIGURE 20