SYSTEM CHECKOUT
Checking Installation
1. Refer to appropriate wiring diagram and
recheck all wiring connections. Ensure that
all connections are tight.
2. Check blower motor and relay box con-
nectors for proper connection.
3. Reinstall control box cover(s).
4. Switch circuit breaker(s) to “ON” position.
5. Set furnace blower selector switch (see
Figure 16) to “AUTO” (EH Units only).
6. Replace outer furnace door.
7. Check all duct connections and tape for air
leakage.
Table 6. Blower Performance
Table 7. Anticipator Settings
Table 8. Clearances
Standard E3EH Blower
with Filter, @ 0.3" ESP
Pin No. Speed CFM
#1 Low 840
#2 High 1160
4-Ton Blower with Coil and
Coil and Filters, @ 0.3" ESP
Pin No. Speed CFM
#1 Low 880
#2 Med.-Low 1170
#3 Med.-High 1310
#4 High 1460
5-Ton Blower, with Coil and
Coil Filters, @ 0.3" ESP
Pin No. Speed CFM
#1 Low 990
#2 Med.-Low 1320
#3 Med.-High 1620
#4 High 1790
Multi-Speed, X13, Blower, with
Coil and Filters, @ 0.3" ESP
Pin No. Speed CFM
#1 Low 880
#2 Med.-Low 1000
#3 Med 1170
#4 Med.-High 1260
#5 High 1460
Furnace
Model
Thermostat
Anticipator Setting
010, 012 0.2
015, 017, 020, 023 0.4
ALL MODELS CLOSET ALCOVE
Front ** 6" 18"
Back 0" 0"
Sides 0" * 0" *
Top 0" 0"
Top and Sides of Duct 0" 0"
Bottom of Duct 0" 0"
** Service Clearance
* For upfl ow application using upfl ow stand, 1” minimum per
side.