NEC P Water System User Manual


 
Central Office Calls, Answering
DSX Software Manual Features 75
Features
Programming
Basic Programming
1. In 3101-01: Line Type (page 809), set the circuit type to match the connected service.
2.
In
3101-03: DTMF Dialing (page 811)
, indicate whether the line is DTMF (
1
) or Dial Pulse (
0
).
3. In 3103-03: Loop Length (page 815) for analog lines only, set this option to compensate for the telco cir-
cuits loop length.
- For normal installations, enter 0.
- If the system is very close to the central ofce or behind a PBX, enter 1.
- If the loop length is abnormally long, enter 2.
1. Review the following timers:
- 160x-Feature Timers (page 669).
- 161x-COI (Analog Line) Timers (page 682).
- 163x-T1/E1 Timers (page 695).
- 164x-T1 Specic Timers (page 700).
- 165x-E1 Specic Timers (page 704).
1. For no incoming or outgoing access, in 2131-[01-64]: Line Access (page 763) enter 0.
2. For incoming access only, in 2131-[01-64]: Line Access (page 763) enter 1.
3. For outgoing access only, in 2131-[01-64]: Line Access (page 763) enter 2.
4. For full access, in 2131-[01-64]: Line Access (page 763) enter 3.
1. For lamp only (no ringing) day and night, in 2132-[01-64]: Line Ringing (page 764) enter 1.
2. For day and night ringing, in 2132-[01-64]: Line Ringing (page 764) enter 2.
3. For night ringing only, in 2132-[01-64]: Line Ringing (page 764) enter 3.
4. For delay ringing day and night, in 2132-[01-64]: Line Ringing (page 764) enter 4.
- In 1604-01: Delay Ring Timer (page 678), set the interval after which a delay ring line will change
from ashing to ringing.
5. For single line telephones:
- In 2102-01: Class of Service (page 724), check the extension’s Class of Service level.
- To have single line telephones ring with a single ring for outside calls, in 1403-02: Single Ring for
Single Line Set (page 635) enter
Yes.
- To have single line telephones follow the ringing pattern of the outside line, in 1403-02: Single
Ring for Single Line Set (page 635) enter No.
1.
Make sure each line’s circuit type and loop length setting match the requirements of the
connected service.
2. Review the system timers for compatibility with the connected service.
3. Set the line access options at extension for each line.
4. Set the line ringing options at extension for each line.