Napoleon Fireplaces NPS40 Stove User Manual


 
W415-0616 / B / 02.18.08
26
Make certain the heater has fully cooled (approximately 25
minutes) before opening the door and conducting service.
To clean the
burn pot, open
the door and
knock away any
debris on the
burn pot. If se-
verely clogged,
remove the burn
pot to gain bet-
ter access.
If removing
the burn pot
set aside on a
non-combustible
surface. See
Figure 39. Once
removed, discard all material that has accumulated in the burn pot.
Make certain that all openings
are clear of any build up of
ash from the ledge below the
burn pot.
DAILY (WHENEVER USING THE HEATER)
CONTINUED
CLEANING THE BURN POT
Re-install the burn pot ensur-
ing it sits level in the heater.
Also must ensure the ignitor
and the burn pot locating notch
line up when reinstalling the
burn pot.
If the pellets build up over the burn pot, turn the pellet feed switch
to "OFF".
If the fl ames seem to be coming only from the sides, or are or-
ange/black, turn the heater off and check for build up of pellets.
The most likely causes are:
1. Feed rate has been set to maximum for an
extended period of time. Turn feed rate to
optimum.
2. The door, glass, or ash pan is open or has an air
leak.
3. The burn pot requires cleaning.
4. The exhaust system requires cleaning.
5. The heater requires adjustment.
6. Poor pellet quality
MAKE SURE PELLETS ARE NOT PILING UP
Figure 39
Figure 38
BI-WEEKLY (OR EVERY 10 BAGS OF
PELLETS)
The more frequently you clean out the fl y ash, the more effi cient
your heater will burn.
The fi re box becomes very hot during operation. Let the
heater cool completely before conducting service.
1. Open the viewing door. See Figure 35 and 36
3. Vacuum out the fi rebox, louvres, air housing and burn pot of all
fl y ash.
4. Replace the louvres and burn pot, latch the viewing door closed
and close both side doors.
VACUUM FIREBOX
Figure 42
2. Lift the burn pot out and set aside on a non-combustible
surface. See Figure 39. Remove the right and left
louvres by lifting the louvres up and out of the fi rebox
setting them on a non-combustible surface.
Figure 41
IGNITOR
LOCATING NOTCH
LOUVRES
AIR HOUSING
FIREBOX
!
WARNING
!