Napoleon Fireplaces NPS40 Stove User Manual


 
W415-0616 / B / 02.18.08
10
GENERAL INSTALLATION
HEATER PLACEMENT
PLANNING YOUR INSTALLATION
Have an authorized Napoleon® dealer install the heater. If you
install the heater yourself, have your dealer review your installation
plans and/or installation.
Draw out a detailed plan of the installation including dimensions
and verify the dimensions with the requirements listed in this
manual.
For built-in enclosures, when determining the location of the
heater, locate the wall studs (for horizontal penetrations). You may
wish to adjust the heater position slightly to ensure the vent does
not intersect with a framing member.
Heater must be positioned so that no combustibles are within, or
can swing within (e.g. drapes, doors), 48" of the front of the heater.
If the heater is placed in a location where the ceiling height is less
than 7' above the base of the heater, the installation must follow
the requirements in the section "Alcove Installations Require-
ments"
INSTALLATION OPTIONS
NPS40:
To install in a Residential or Mobile Home see the section "Mobile
Home Requirements".
For alcove installations see the section "Alcove Installation
Requirements".
For horizontal vent or vertical vent see the section "General Vent-
ing".
See the section "Outside Air" for this option.
NPI40:
The insert can be adapted to vent out the rear or vertically.
To install as an insert into an existing masonry fi replace factory
built fi replace or a built in combustible enclosure see Insert Instal-
lation.
FLOOR PROTECTION REQUIREMENTS
NPS40:
The heater must be installed on a non-combustible fl oor protector
extending the full depth of the heater and extending a minimum 6"
in front and on either side (minimum .018" thick - 26 gauge).
The fl oor protector must extend under and 2" beyond each side
and rear of a "Tee" (if used).
NPI40:
In the case of the NPI40, the fl oor protector must have a R-value
of 0.4 hr ft²°F
BTU
READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS HEATER. FAILURE TO
FOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
Check with local building offi cials for any permits required for
installation of this pellet heater and notify your insurance company
before proceeding with installation.
Before installing we recommend placing the heater outside and
load 5 pounds of pellets inside the hopper. Plug the heater in and
let it run on HIGH until the pellets run out. This will cure the paint
and burn off the oils on the steel, there by minimizing any smell
inside the home.
Electrical Rating 115 Volts, 3.6 Amps, 60Hz
Watts During Start-Up Se-
quence
400 (approximately)
Watts During Operation 180 (approximately)
NPS40 Width 22 3/8"
NPS40 Height 30 1/2"
NPS40 Depth 26 5/8"
Weight 210 Pounds
Exhaust Collar 3"
Intake Collar 2"
NPS40 Hopper Cap. 55 Pounds
NPI40 Hopper Cap. 45 Pounds
EPA Exempt
Burn Rate** 1.0 to 5.0 (Pounds Per Hour)
BTU/h** 8500 to 42500
Minimum Fireplace Opening
Size
Front: 22 1/2* W x 20 5/8 H x
14 1/4 D
Back: 20 3/8 W
This heater is EPA exempt from Phase II requirements, but has
been tested for emissions using EPA test methods by Warnock
Hersey.
SPECIFICATIONS EPA COMPLIANCE
* In order to install fl ashing fl ush to fi nished wall and centered
within the opening the front opening of the fi replace or enclosure
must be 32 5/8" wide.
!
WARNING