Napoleon Fireplaces GT8N Indoor Fireplace User Manual


 
13
W415-0619 / B / 03.03.08
Do NOT use the fireplace if any part has been
under water. Call a qualified service technician
IMMEDIATELY to have the replace inspected for
damage to the electrical circuit.
IT IS NECESSARY TO HARD WIRE THIS
FIREPLACE.
Permanently framing the replace with an enclosure,
requires the fireplace junction box to be hard
wired.
This replace must be electrically connected and
grounded in accordance with local codes. In the
absence of local codes, use the current CSA C22.1
CANADIAN ELECTRICAL CODE in Canada or
the ANSI/NFPA 70-1996 NATIONAL ELECTRICAL
CODE in the United States.
ELECTRICAL CONNECTION
HARD WIRING CONNECTION
FIGURE 18
!
WARNING
RISK OF ELECTRIC SHOCK!
Control and valve operate with 110v.
12
34
YELLOW
BROWN
W
H
I
T
E
PURPLE
B
L
A
C
K
IGNITOR
WIRE
IGNITOR
GAS
VALVE
SWITCH
CONTROL MODULE
GROUND
110v
POWER
SUPPLY
JUNCTION BOX
(c/w 2 receptacles)
GROUND
Proceed once the vent installation is complete.
Note: All gas connections must be contained within the replace when
complete.
1. The replace is designed to accept a 1/2” gas supply line. The replace is
equipped with a 1/2” manual shut-off valve.
2. The access to the gas inlet is located on the bottom of the outer shell.
3. The shut off must always be within the outer shell.
4. When exing any gas line, support the gas valve so that the lines are not
kinked.
5. Check for gas leaks by brushing on a soap and water solution.
Do not use open ame.
GAS INSTALLATION
FIGURE 17
FIGURE 16
STAND-OFF ASSEMBLY
1
FIGURE 19a&b
2