Napoleon Fireplaces GDS28P Indoor Fireplace User Manual


 
27
W415-0153 / B / 06.10.10
4.7.2 INSTALLING "B" VENT
Follow the instructions of the "B" vent manufacturer for chimney
installation.
A. Remove and discard the two combustion air cover plates
and gaskets located on the rear panel of the appliance.
B. Replace the four screws per side to secure the rear
panel to the appliance.
C. Remove the spill switch bracket from the rear of the
adapter.
D. Gently pull the two wire terminals (located inside the 7"
ue collar at the top of the appliance) out approximately
8".
E. Bring the wires through the lower hole in the adapter and
out the spill switch opening. To pass the wires through the
hole more easily, temporarily tape the two terminals together.
F. With the spill switch opening aligned to the back of the
appliance, push the crimped edge of the adapter in to the
appliance ue collar.
G. Connect the wire terminals to the spill switch and re-secure
the bracket.
H. Secure the terminal block into place as shown with the screw
supplied.
I. Unscrew the wire access cover plate from the rear right hand
side below the rebox. Remove and discard the gasket.
Remove the knockout from the cover plate and insert the
protective bushing. Pull both spill switch wires through the
bushing taking up any slack. Replace the cover plate. Connect one wire end to the terminal block and
the other end to terminal 1 of the gas valve. Connect the two wires running down the left side of the
unit from the on/off switch to the remaining tab on the terminal block and to terminal 3 on the gas valve.
For aesthetics, the adapter
has been designed to accept a
standard matte black 7" stove
pipe and the decorative band
(standard with the GS-150KT).
Both are available from your local
authorized dealer / distributor.
4.7.3 B-VENT
Attach the B-Vent label, shown, in the control area of the appliance.
ATTACH THIS LABEL IN THE CONTROL AREA OF THE FIREPLACE.
THIS FIREPLACE HAS BEEN CONVERTED TO A ‘B’VENT MODEL.
ATTACHEZ CET ETIQUETTE DANS LA REGION DE CONTROLE DU FOYER.
CE FOYER A ETE CONVERTI A UN MODELE A SYSTEME D’EVACUATION ‘B’.
WS-385-160
SPILL
SWITCH
ADAPTER
COMBUSTION AIR COVER
PLATES AND GASKET
TERMINAL BLOCK
WIRE ACCESS