18
W415-0547 / B / 05.08.06
1. Attach the adjustable pipe to the last section of rigid pip-
ing. Secure with screws and seal.
2. Install the 4" aluminium fl exible liner
to the stove. Secure with 3 screws
and fl at washers. Seal the joint
and screw holes using high
temperature sealant.
3. Run a bead of high tem-
perature sealant Mill Pac
around the inside of the air
intake collar. Pull the adjust-
able pipe a minimum 2" into
the air intake collar.
ENSURE THAT THE SEAL-
ANT IS NOT VISIBLE ON THE EXTERIOR PIPES ONCE
INSTALLATION IS COMPLETED. AN OPTIONAL DECO-
RATIVE BRASS BAND IS AVAILABLE FOR THIS USE.
(STANDARD WITH A GD175 KIT AND GD-176). IN THE
EVENT THAT THE VENTING MUST BE DISASSEMBLED,
CARE MUST BE TAKEN TO RESEAL THE VENTING.
In Canada, mobile home installation may be vented horizon-
tally or vertically. In the United States, it may only be installed
vertically. See "Vertical Venting" or "Horizontal Air Terminal
Installation" for installation.
For mobile home installations, the fi replace must be fastened
in place. It is recommended that the fi replace be secured in
all installations. Use the levelling/securing kit, GDSLL-KT for
this purpose.
SEALANT
2" OVERLAP
SELF DRILLING
#8x1/2"
SCREWS
HI-TEMP
STOVE VENT CONNECTION
MOBILE HOME INSTALLATION
1/2FPT
3/8NPT
CONNECTOR
FITTING
ADAPTER
FLEXIBLE
PIPE
BLACK
VALVE
SHUT OFF
1. Install rigid black pipe, or 1/2" type L copper tubing with a
shut-off valve to the stove.
2. Seal and tighten the gas line securely to a fl ex connec-
tor.
DO NOT KINK FLEXIBLE CONNECTOR.
3. Check for gas leaks by brushing on a soap and water solu-
tion. DO NOT USE OPEN FLAME.
FIGURE 28
GAS INSTALLATION
RESTRICTOR
SHOWN IN A FULLY
CLOSED POSITION
RESTRICTING VERTICAL VENTS
Vertical installations may display a very active fl ame. Loosen
the two screws and slide the restrictor plate blocking the ex-
haust path. This reduces the velocity of the exhaust gases,
slowing down the fl ame pattern and creating a more traditional
fl ame appearance. For vertical vents greater than 15 feet, this
restrictor must be fully closed.
FIGURE 27
RESTRICTOR
SHOWN IN A FULLY
OPEN POSITION