BLOWER REPLACEMENT
The Napoleon MADISON comes equipped with a heat circu-
lating blower. The blower is pre-wired and is controlled by
the remote control supplied with the unit. For control details,
see operation. Pg . 22.
Drywall dust will penetrate into the blower bearings,
causing irreparable damage. Care must be taken to pre-
vent drywall dust from coming into contact with the
blower or its compartment. Any damage resulting from
this condition is not covered by the warranty policy.
1. Turn off the power to the fireplace.
2. Turn off the gas valve.
3. Remove the glass door, logs, rear log support, side brick
panels, rear baffle, and rear panel.
4. To remove the lamp assembly, remove the two log locat-
ing studs located just behind the main burner. It is not neces-
sary to disconnect the wires, the assembly can lay along the
right side of the firebox.
5. The blower mounting plate can now be removed. Remove
the six screws that secure the plate to the firebox back. The
blower is secured to this plate.
6. Disconnect the wire connectors and ground before attempt-
ing to remove the blower from the plate.
7. When re-installing the replacement blower, it will be nec-
essary to replace the gasket (W290-0091) on the cover plate.
1. Turn off the power to the unit.
2. Turn off the gas valve.
3. Remove the door and logs.
4. Loosen the lense retainer screws and pivot the retainers
out of the way.
5. Using a small flat screwdriver, gently lift the orange lense
from the housing.
LAMP REPLACEMENT
6. Slide the defective bulb to either side until the opposite
end is disengaged. Remove the bulb lifting the disengaged
end.
7. Replace with a 75 watt halogen lamp (E-11 BASE).
Install the replacement bulb using the protective wrap
to avoid touching the lense, then disgard the protec-
tive wrap.
8. Repeat steps 5 - 1 for installation.
FIGURE 41
FIGURE 43
FIGURE 42
FIGURE 44