INSTALLATION
AND OPERATION
INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada s (705)721-1212 s fax(705)722-6031
www.napoleonreplaces.com s ask@napoleon.on.ca
CERTIFIED UNDER U.S. ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 AND THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY (D.E.Q.) PARTICULATE
EMISSION STANDARDS BY E.E.M.C THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO STANDARDS: CSA B366.2, ULC S627, UL 1482. MODEL
1100 HAS BEEN TESTED AND LISTED FOR INSTALLATION IN MOBILE HOMES.
EPA 1100, 1100L, 1100C, 1150,
1400, 1400L, 1450 & 1900
FREE STANDING MODELS
EPI 1101, 1402
INSERT MODEL
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE
SAFETY INFORMATION
- This fireplace can be very hot when burning.
- Combustible materials such as firewood, wet clothing, etc. placed too close can catch fire.
- Children and pets must be kept from touching the fireplace when it is hot.
- The chimney must be sound and free of cracks. Before installing this unit, contact the local
building or fire authority and follow their guidelines.
- Operate only with the door tightly closed.
- Burn wood behind the log retainer directly on the firebricks.
- Do not use an elevated grate or otherwise raise the fire.
- At least 14 square inches of outside air must be admitted to the room or directly to the unit
through a 4” diameter pipe.
- This fireplace is designed to burn natural wood only. Higher efficiencies and lower emissions
generally result when burning air dried seasoned hardwoods, as compared to softwoods or
to green or freshly cut hardwoods.
- Do not start a fire with chemicals or fluids such as gasoline, engine oil, etc.
- Do not burn treated wood, coal, charcoal, colored paper, cardboard, solvents or garbage.
- Do not let the fireplace become hot enough for any part to glow red.
- KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C). Attempts to acheieve
heat output rates that exceed design specifications can result in steel distortion and
damage.
If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage, bodily injury or even death. Please read
entire manual before you install and use your fireplace.
This fireplace has not been tested with an unvented gas log set. To reduce
risk of fire or injury, do not install an unvented gas log set into the fireplace.
!
WARNING