Napoleon Fireplaces GD82NT Indoor Fireplace User Manual


 
21
W415-0536 / C / 09.06.06
REMOTE, RECEIvER AND vALvE ACCESS
1a. Rectangular Front Removal

the male portion of the latch disengages. Tilt forward slightly
and lift from the 2 shoulder screws near the bottom.
1b. Heritage and Wrought Iron Front Removal
Remove the two screws in the slots located behind the inner
arch. (Fig. 50) Tilt forward slightly and lift from the 2 shoulder
screws near the bottom front. Note: Fronts are heavy so
when the second screw is removed the front will want
to fall forward.
2. Control Panel Removal
Lift the panel from the slots. This will allow access and removal
of the remote receiver and spark module.
If valve replacement is necessary following steps 1 and 2
above then proceed with the following ...
3. Door Removal

Pull the latch forward then lift hook out from slot in the door.
Pivot door forward then lift out from retainer along the bottom

4. Burner Removal
The phasoramic burner must be removed next. Remove the
   
the 3 screws holding the burner - 2 at the back and 1 at the
front (Fig. 52).

5. Next, remove the 5 screws that secure the burner base.
Once the gas has been disconnected, the burner train as-
sembly will lift out.
BURNER ASSEMBLY REMOvAL
AIR
DEFLECTOR
BURNER
FIGURE 51
FIGURE 52
FIGURE 50