Napco Security Technologies GEM-K4 Home Security System User Manual


 
17
FUNCTION MENU
9. Reset System Trouble? System troubles display and sound at the keypad. Correcting
the trouble will clear most indications, however the following error codes will require manual
reset: E11; E13; E19; E20 and E22. (See SYSTEM TROUBLE ERROR CODES for a
description of error codes).
10. Reset Sensor Watch Failure (Sensor Watch programmed? YES NO).
Your system may have been programmed for Sensor Watch, a feature which supervises the
motion sensors in the system. If a Sensor Watch failure occurs, a System Trouble E22-NN
will result, where NN represents the zone number of the sensor in question. To reset, press
C to clear the display, enter the Function Menu, scroll to Reset Sensor Watch Failure
and press U. If you cannot correct the problem, call for service.
(Note: This function available with GEM-P9600 and GEM-P3200 control panels only. With the GEM-P816/1632
panels, "Sensor Watch Fail" is reset by "Reset System Trouble" function).
11. Start Exit Time? (Optional) (Start Exit Time programmed? YES NO)
In Commercial Burglary systems, exit delay may have been programmed to start after a
central-station “ringback” (verification) signal has been received. If the ringback tone has not
been received within about 30 seconds after arming, a communication problem may exist.
Use this function to start exit delay manually, then exit the premises immediately. Be sure to
have your alarm specialist check communications with the central station as soon as
possible.
(Note: This function available with GEM-P9600 and GEM-P3200 control panels only).
CHIME
09
CHIME
10
CHIME
11