TROUBLESHOOTING
If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and


WARNING
  REMEDY

goes out when control

1. Control knob not fully pressed in. 1. Press in control knob fully.
2. Control knob not pressed in long
enough.
2. After ODS/pilot lights, keep control knob
pressed in for 30 seconds.
3. Manual shutoff valve not fully open. 3. Fully open manual shutoff valve.
4. Thermocouple connection loose at
control valve.
4. Hand tighten thermocouple connection
until snug, then tighten 1/4 turn more.
5. Pilot ame not touching thermocouple,
which allows thermocouple to cool,
causing pilot ame to go out. This
problem could be caused by either
low gas pressure, or a dirty or partially
clogged ODS/pilot.
5. Contact local gas company.
6. Thermocouple damaged. 6. Replace thermocouple.
7. Control valve damaged. 7. Replace control valve.
Burner does not light after

1. Burner orice is clogged. 1. Burner orice is clogged.
2. Burner orice diameter is too small. 2. Burner orice diameter is too small.
3. Inlet gas pressure is too low. 3. Inlet gas pressure is too low.
 
combustion
1. Manifold pressure is too low. 1. Contact local gas company.
2. Burner orice is clogged. 2. Clean burner or replace burner orice.
Slight smoke or odor

1. Burner orice is clogged or damaged. 1. Clean burner or replace burner orice.
2. Burner is damaged. 2. Replace burner.
3. Gas regulator defective. 3. Replace gas regulator.
Logs appear to smoke

1. Vapors from paint or curing process of
logs.
1. Problem will stop after a few hours of
operation. Run the heater with the damper
open if you have one, or open a window
for the rst few hours.
2. Log heater is intended to be smokeless.
Turn OFF heater and call qualied service
person.
H e a t e r p r o d u c e s a
whistling noise when

1. Turning control knob to HIGH position
when burner is cold.
1. Turn control knob to LOW position and let
warm up for a minute.
2. Air in gas line. 2. Operate burner until air is removed from
line. Have gas line checked by local gas
company.
3. Dirty or partially clogged burner orices. 3. Clean burner or replace burner orice.
 1. LP-regulator shut down due to inlet
pressure too high.
1. Verify LP tank regulator is installed and
set at 11" to 13" w.c.
2. Replace regulator on heater.