Monessen Hearth MJ27PR Indoor Fireplace User Manual


 
16 86D0024
14" Minimum
FP2004
min clear nocomb floor
Heater in
Fireplace or
Firebox
Combustible
Material
This Distance May Now be
Less Than 1
3
/8"
FP2004
FLOOR CLEARANCE
The gas log heater must be installed at least 1
3
/8" above any combustible ooring material, such as carpeting or
tile, which is closer than 14" to the base of the replace. The minimum distance must be maintained from the top
surface of carpeting, tile, etc. Figure 10
OR
The gas log heater may be installed nearer to the oor if a minimum of 14" of noncombustible material such as
slate or marble is installed between the base of the replace and the combustible ooring. Figure 11
1
3
/8" Minimum
FP2003
min clear comb floor
Heater in
Fireplace or
Firebox
Combustible
Material
FP2003
Figure 10 - Minimum Clearance above Combustible Flooring
Figure 11 - Minimum Clearance above Combustible Flooring with
Noncombustible Material Installed at Base of Fireplace