86D0024 17
FP2005
damper install
Damper Stop
Damper
FP2005
• Turn off gas supply to replace or rebox.
• Have the replace oor and chimney professionally cleaned to remove ashes, soot, creosote or other obstruc-
tions. Have this cleaning performed annually after installation.
• Seal any fresh air vents or ash clean-out doors located on oor or wall of replace. If not, drafting may cause
pilot outage or sooting. Use a heat-resistant
sealant.
Install and operate the appliance as directed
A damper stop must be provided with the unit.
Contact your dealer to obtain one. The damper
stop must be installed as shown in Figure 12 to
prevent full closure of the replace damper blade
and provide a minimum 29 square inch ue opening.
Figure 12 - Damper Stop Installation.
BEFORE FULLY INSTALLING THE UNIT:
• Turn OFF the gas supply to the replace or rebox.
• Seal any fresh air vents and/or ash clean-out doors located on the oor or wall of the replace. If left unsealed,
drafting may cause pilot outage or sooting. Use a heat resistant sealant.
Manual and Millivolt controlled gas logs may be installed as a vented decorative log set in compliance with ANSI
Z21.60 and National Fuel Gas Code, Section 6.6. Since, the gas logs are operated with the damper open,
WARNING
Exception:
instructions stating that it has not been tested or should not be used with unvented
WARNING
Before installing in a solid fuel burning
be cleaned of soot, creosote, ashes and loose
WARNING
(check with a match or a smoke stick), reposition the damper clamp until a positive