Monessen Hearth 624DV(ST Indoor Fireplace User Manual


 
36
42D0200
Designer Series Gas Fireplaces

PILOT
O
F
F
P
I
L
O
T
O
N
FP1935
control knob pilot
Continued on next page

You may check for gas leaks with the following methods
only:
Soap and water solution
An approved leak testing spray
Electronic sniffer
     
    



NOTE: Remove any excessive pipe
compound from the connections.
Excessive pipe compound can set off
electronic sniffers.







1. Depress and turn knob counterclockwise
to pilot position.
2. Depress fully and hold pilot gas knob. The elec-
tronic ignitor will automatically ignite the pilot.
Keep knob fully depressed for a few seconds.
Release and check that pilot continues to
burn.
If the pilot does not stay lit, repeat steps 1 and 2.

Figure 49 -
Pilot Position
Check for gas leaks in each of the following locations:
Pipe from the gas supply line connection to the gas valve
Burner connections Field made joints / gas shutoff valve
Pilot Factory made joints
Each joint or connection All joints on valve and control body
      


