Monessen Hearth 624DV(ST Indoor Fireplace User Manual


 
28
42D0200
Designer Series Gas Fireplaces

A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach
the wall switch in a junction box at the desired location on the wall. Figure 38. Do not extend beyond
the wall switch wire length provided.
 Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire
is permitted if the wire is made out of larger gauge (diameter) wire. Always check with local code.
Figure 38 -
Wiring Diagram for Wall Switch




ON
OFF
OPTIONAL REMOTE
WALL SWITCH
ON
OFF
OPTIONAL REMOTE
WALL SWITCH
PILOT
HI
LO
ON
OFF
TH
TP
TH/TP
ON
OFF
RS
FP1980
Dv wiring diagram