Mitsubishi Electronics PURY-P72 Air Conditioner User Manual


 
[ V Electrical Wiring Diagram ]
- 101 -
HWE0803A GB
(6) CMB-P1013,1016NU-GA models
CNTR
(Red)
CN41(Green)
CN40
(Yellow)
CN34(Black)
CN33(Red)
CN35(Blue)
ZNR01
ZNR02
CN06
54
3
2
1
LEV2
CN07
CN13
CNP1
(Blue)
CNVCC1
(Yellow)
CN03
M1
M2
TB02
S(SHIELD)
6
54
3
2
1
LEV3
213
CNVCC2
312
CONT.B
CN39
13
CNOUT3
CNOUT1
13
1
2
3
1
2
3
CNP3
2
1
1
2
3
4
5
6
7
8
4
3
2
1
12321
CN02
CN10
CN11
TH11
TH12
TH15
TH16
TR
CN38
CN26
3
1
4
1
2
3
4
5
6
7
8
3
2
1
PS1
PS3
X45
X42
X43
X40
X44
X47
X46
CN42
X41
SV1B
SV1A
SV1C
5
6
7
8
9
10
11
12
13
14
15
16
3
2
4
8
9
10
11
12
13
3
2
4
5
6
7
14
15
16
4
3
2
SV2C
SV2A
SV2B
SV3C
SV3A
SV3B
SV4C
SV4A
SV4B
SV5B
SV5A
SV5C
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
SV6B
SV6A
SV6C
1
2
3
4
1
2
3
4
33
2
1
2
1
CN31(Yellow)
CN30(Black)
CN29(Green)
CN28(Blue)
CN27(Red)
X35
X11
X12
X34
X9
X10
X33
X7
X8
X32
X5
X6
X31
X3
X4
X30
X1
X2
7
5
3
1
7
5
3
1
7
5
3
1
7
5
3
1
7
5
3
1
7
5
3
1
11
1
1
SV7A
SV7B
SV7C
SV8B
SV8A
SV8C
SV9B
SV9A
SV9C
SV10B
SV10A
SV10C
16
16
131415
9
101112
5
6
78
4
4
5
6
87
9
12 11 10
15 14 13
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
CN32
753133
X14
X13
X36
X37
X15
X16
X38
X39
X17
X19
X18
X20
753175317531
1
CN36(Green)
X21
CN45(Green)
CN44(Yellow)
CN43(Red)
REL.B
4
5
6
8
9
7
10
12
11
13
15
14
16
3
4
2
1
SV11B
SV11A
SV11C
1
3
2
8
9
10
11
12
13
3
2
4
1
5
6
7
14
15
16
4
3
2
1
SV12C
SV12A
SV12B
SV13C
SV13A
SV13B
SV14C
SV14A
SV14B
SV15B
SV15A
SV15C
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
SV16B
SV16A
SV16C
1
2
3
4
1
3
4
3
4
2
1
X51
X55
X56
X52
X53
X57
X54
7
7
5
3
1
7
5
3
1
X48
X50
X49
5
7
7
5
3
1
7
5
3
1
5
3
1
3
1
SVM2
SVM1
3
22
3
1
1
2
CN05
6
54
3
2
1
LEV1
L2
L1
TB01
1
35
CN12
1
2
3
8
7
6
5
4
3
2
1
4
CNOUT2
CNOUT4
3
3
1
CN46(Yellow)
X60
CONT.B
Terminal block
(for Transmission)
TB02
Terminal block
(for power source)
TB01
Solenoid valve
Expansion valve
Thermistor sensor
Transformer
Name
Symbol
SV1~16A,B,C
TR
TH11,12,15,16
LEV1~3
PS1,3
Pressure sensor
SVM1,2
T1~16
Terminal
Solenoid valve
F01
Fuse AC250V 6.3A F
Note:1.TB02 is transmission terminal
block.Never connect power line
to it.
2.The initial set values of switch
on CONT.B are as follows.
SW1:0
SW2:0
6
Indoor/outdoor (heat source)
Transmission line
2
2
1
3
1
3
T1
T5
T4
T3
T2
T6
T10
T9 T8
T7
T11
T15
T14
T13
T12
T16
PULL BOX
FUSE(15A)
BREAKER(15A)
INDOOR UNIT
TO NEXT
POWER SUPPLY
~208V-230V
60Hz
G
G
1
ON
SW4
8
OFF
SW5
OFF
ON
81
(Blue)
DSA
(Blue)
(Yellow)
(Red)
(Black)
10 1
SW1SW2
CMB-P1016NU-GA ONLY
(Red)
F01
250VAC
6.3A F
Relay
REL.B
BC controller
Circuit
board
(Symbol explanation)