Condition
Standard temperature
Maximum temperature
MInimum temperature
Maximum humidity
Standard temperature
Maximum temperature
MInimum temperature
80
95
67
80
70
80
70
67
71
57
75
60
67
60
95
115
23
80
47
75
17
75
75
43
65
15
Function
Cooling
Heating
Model
Airflow
(
CFM
)
Air speed
(
ft/sec
)
Coverage
range
(
ft
)
PKH18FK
PKH24FK
PKH30FK
PKH36FK
710
710
990
990
16.1
16.1
17.7
17.7
41
41
50
50
Air intake temperature
Indoor
DB
(
˚F
)
WB
(
˚F
)
Outdoor
DB
(
˚F
)
WB
(
˚F
)
Model
Outdoor unit
precharged
(
up to 100ft
)
25ft
0
0
0
0
40ft
0
0
0
0
55ft
0
0
0
0
70ft
0
0
0
0
85ft
0
0
0
0
100ft
0
0
0
0
115ft
2
2
5
5
130ft
4
4
10
10
150ft
7
16
16
164ft
9
20
20
Refrigerant piping length (one way)
PKH18FK
PKH24FK
PKH30FK
PKH36FK
5 lbs 8 oz
9 lbs 15 oz
10 lbs 2 oz
10 lbs 9 oz
5. OPERATING RANGE
1) POWER SUPPLY
6. OUTLET AIR SPEED AND COVERAGE RANGE
7. ADDITIONAL REFRIGERANT CHARGE (R-22(oz))
1 Phase 60Hz 208/230V
Guaranteed voltage range
2) OPERATION
Min. Max.
198V 208V 230V 253V
The air coverage range is the value up to the position
where the air speed is 0.8ft/sec. when air is blown out
horizontally from the unit at the High notch position.
The coverage range should be used only as a general
guideline since it varies according to the size of the
room and furniture installed inside the room.