1. POWER SUPPLY
1 Phase 60 Hz 208/230 V
Normal Voltage Range: 187 to 252
(Rated in accordance with ARI Standard 110)
2. OPERATING TEMPERATURE RANGE
FUNCTION
AIR INTAKE
CONDITION
INDOOR OUTDOOR
DB (°F) WB (°F) DB (°F) WB (°F)
Cooling
Standard temperature Maximum
temperature Minimum temperature
Maximum humidity
80 67 95 75
95 71 115 -
67 57
55
1
1. A low ambient accessory kit is required for operation below this temperature which extends cooling operation to 25°.
-
80 75 80 75
Heating
Standard temperature Maximum
temperature Minimum temperature
70 60 47 43
70 60 17 15
80 67 75 65
OPERATING RANGE8