Mitsubishi Electronics PKH36FL Air Conditioner User Manual


 
44
4. HOW TO CHECK THE PARTS
Room temperature
thermistor (RT1)
Pipe temperature
thermistor (RT2)
Fan motor (MF)
Disconnect the connector, then measure the resistance using a tester.
(Surrounding temperature 50°F to 86°F)
Measure the resistance between the terminals using a tester.
(Refer to the thermistor)
Normal
4.3k' to 9.6k'
Abnormal
Open or short
Motor terminal
or
Relay connector
Normal
PKH
18,24FL
Abnormal
Red-White
99.5'i10%
Open or short
White-Black
103.5'i10%
1
1
3
3
5
5
Red
White
Black
Relay connector
Protector
Parts name Check points
0
10
20
30
40
50
-4 14 32 50 68 86 104 122
< Thermistor for lower temperature >
Temperature (°F)
Resistance (K")
<Thermistor Characteristic graph>
Room temperature thermistor(RT1)
Pipe temperature thermistor(RT2)
Thermistor R0=15k' ±3%
Fixed number of B=3480k' ±2%
Rt=15exp { 3480( ) }
32°F 15k'
50°F 9.6k'
68°F 6.3k'
77°F 5.4k'
86°F 4.3k'
104°F 3.0k'
Thermistor for
lower temperature
1
273+t
1
273
30,36FL
62.6'i10%
74.0'i10%
Vane motor (MV)
Measure the resistance between the terminals using a tester.
(Surrounding temperature 68°F to 86°F)
Normal
186 to 214'
Abnormal
Open or short
3 6 1
4
5
2
M
Pink
Connector
Red
Orange
Blue
Brown
Yellow
Brown-Yellow
Brown-Blue
Red-Orange
Red-Pink
Opening and closing temperature of protector.
Open: 266i41°F (Fan motor OFF)
Close: 176i68°F (Fan motor ON)
OC276-A-2.qxp 03.11.25 9:06 AM Page 44