Mitsubishi Electronics PKH36FL Air Conditioner User Manual


 
39
2-10 INDOOR FAN CONTROL
Indoor fan relay output.
(a) During fan ON
The indoor fan relay turns ON. One second later, the phase control will start.
(b) During fan OFF
The phase control turns OFF. One second later, the indoor fan relay will turn OFF.
5. SW6 (Address selector)
1 2 3 4
ON
OFF
6. SW7 (Model selector)
Switch to set the output of phase-controlled indoor fan motor.
Address setting is available at any time.
The initial factory setting by is based on each capacity.
Service Ref.
SW7
PKH30FL PKH36FL
1 2 3
ON
OFF
1 2 3
ON
OFF
PKH24FL
1 2 3
ON
OFF
PKH18FL
1 2 3
ON
OFF
7. SW8 (Option)
SW8-1~2) Not for use.
SW8-3~4) Not for use.
SW8-5) Not for use.
SW8-6) OFF:For 230V power supply
ON: For 208V power supply
1 2 3 4
ON
OFF
56
8. SW9 (Model selector)
SW9-1~5) Keep this switch.
1 2 3 4
ON
OFF
5
This switch is not available for series PKH.