11
NOTE:
• The operation settings are memorized when 10 seconds have passed after the indoor unit was operated with the
remote controller.
• If main power is turned OFF or a power failure occurs while AUTO START/STOP timer is active, the timer setting is
cancelled.
• If the unit has been off with the remote controller before power failure, the auto restart function does not work as the
power button of the remote controller is OFF.
• To prevent breaker OFF due to the rush of starting current, systematize other home appliance not to turn ON at the
same time.
• When some air conditioners are connected to the same supply system, if they are operated before power failure, the
starting current of all the compressors may flow simultaneously at restart.
Therefore, the special counter-measures are required to prevent the main voltage-drop or the rush of the starting
current by adding to the system that allows the units to start one by one.
7-3. AUTO RESTART FUNCTION
When the indoor unit is controlled with the remote controller, the operation mode, the set temperature, and the fan speed
are memorized by the indoor electronic control P.C. board. “AUTO RESTART FUNCTION” automatically starts operation
in the same mode just before the shutoff of the main power.
Operation
If the main power has been cut, the operation settings remain.
After the power is restored, the unit restarts automatically according to the memory.
(However, it takes at least 3 minutes for the compressor to start running.)
How to release “AUTO RESTART FUNCTION”
Turn off the main power of the unit.
Solder the Jumper wire JR07 on the indoor electronic control P.C. board. (Refer to 9-7.)
JR07
CN151 CN211CN112 CN1R1
CN212
CN1T1
CN1U1
CN130
IC156
Area Left Center Right
Where is the indoor unit installed in your room?
(Left) (Center) (Right)
Position of
the slide
switch
Display on
the remote
controller
Installed at left, if the
distance is not more
than 19-3/4 inch (50 cm).
Installed at right, if the
distance is not more
than 19-3/4 inch (50 cm).
NOTE:If the indoor unit is installed more than 19-3/4 inch (50 cm) away from the side walls, cabinets or other nearby
objects, set the slide switch to the “center” position.
Is the indoor unit
installed at right,
left or center?
Slide swich
7-4. REMOTE CONTROLLER
Be sure to set the slide switch inside the remote controller to an appropriate position in accordance with the installed
position of the indoor unit. If the switch is not set correctly, the air conditioner may not function properly.