SPECIFICATION
3
T3.15AL250V
NSEJ001DA1 12V DC 100" (at 25˚C)
MP20Z 12V DC 300" (at 25˚C)
MSBPC20M16 12V DC 250" (at 25˚C)
MSBPC20M11 12V DC 300" (at 25˚C)
ERZV14D471
A2TPMI334F0V50HSOBA060P5L1J4S 5V DC
3P
INDOOR UNIT
Item
Model
Fuse
Front panel driving motor
i-see Sensor motor
Horizontal vane motor
Vertical vane motor
Varistor
i-see Sensor
Terminal block
MSZ-FA25VA
-
E1
MSZ-FA35VA
-
E1
(F11)
(MP)
(MT)
(MV1)
(MV2)
(NR11)
(RR)
(TB)
Specifications and rating conditions of main electric parts
MSZ-FA25VA -
E1
MSZ-FA35VA -
E1
Indoor model
Function
Power supply
Single phase
230V,50Hz
10
0.25
33
57
0.25
RC0J40-EB
780O298O198
10
4
42
36
W
/29
W
/21
W
4
10
10
10
KM05A
Cooling
594
474
W
/354
W
/252
W
1,220
1,010
W
/800
W
/610
W
Heating
612
498
W
/384
W
/264
W
1,250
1,050
W
/850
W
/640
W
Single phase
230V,50Hz
10
0.25
33
57
0.25
RC0J40-EB
780O298O198
10
4
42
36
W
/29
W
/22
W
4
10
10
10
KM05A
Cooling
594
474
W
/354
W
/258
W
1,220
1,010
W
/800
W
/630
W
Heating
612
498
W
/384
W
/276
W
1,250
1,050
W
/850
W
/660
W
Air flow(Super High)
Air flow(High
W
/Med.
W
/Low
W
)
Power outlet
Running current 1
Power input 1
Auxiliary heater
Power factor 1
Fan motor current 1
Model
Dimensions WOHOD
Weight
Air direction
Sound level(Super High)
Sound level(High
W
/Med.
W
/Low
W
)
Fan speed(Super High)
Fan speed(High
W
/Med.
W
/Low
W
)
Fan speed regulator
Thermistor RT11(at25:)
Thermistor RT12(at25:)
Thermistor RT13(at25:)
Remote controller model
K /h
K /h
A
A
W
A(kW)
%
A
mm
kg
dB(A)
dB(A)
rpm
rpm
k"
k"
k"
Electrical
data
Fan motor
Special
remarks
Capacity
MSZ-FA25VA -
E1
MSZ-FA35VA -
E1
Indoor model
Function
Cooling
546
450
W
/348
W
/252
W
1,130
960
W
/790
W
/610
W
Heating
540
420
W
/372
W
/264
W
1,120
910
W
/830
W
/640
W
Cooling
516
W
/390
W
/258
W
1,080
W
/860
W
/630
W
Heating
522
W
/402
W
/276
W
1,090
W
/880
W
/660
W
Air flow(Super High)
Air flow(High
W
/Med.
W
/Low
W
)
Sound level(Super High)
Sound level(High
W
/Med.
W
/Low
W
)
Fan speed(Super High)
Fan speed(High
W
/Med.
W
/Low
W
)
K /h
K /h
dB(A)
dB(A)
rpm
rpm
Special
remarks
Capacity
42
36
W
/29
W
/21
W
642
42
36
W
/29
W
/22
W
1,300
NOTE : Test conditions are based on ISO 5151
Cooling : Indoor Dry-bulb temperature 27:Wet-bulb temperature 19:
Outdoor Dry-bulb temperature 35:Wet-bulb temperature 24:
Heating : Indoor Dry-bulb temperature 20:Wet-bulb temperature 15:
Outdoor Dry-bulb temperature 7: Wet-bulb temperature 6:
Refrigerant piping length (one way): 5m
w Reference value
1 Measured under rated operating frequency.
When outdoor unit is MXZ type.