Connection to the gas supply, or
conversion from one type of gas to
another, should only be undertaken
by an approved and registered gas
installer in strict accordance with
local and national safety and
building regulations (e.g. Gas Safe
registered in the UK).
When converting to a different type of
gas, the main jets and the small jets
have to be changed.
CS 1012-1
Nominal rating at high setting
Gas type kW
Medium
burner
Natural gas H
Liquid gas
1.80
1.80 / 131 g/h
Large
burner
Natural gas H
Liquid gas
3.00
3.00 / 218 g/h
Total output Natural gas H
Liquid gas
4.80
4.80 / 349 g/h
Nominal rating at low setting
Gas type kW
Medium
burner
Natural gas H
Liquid gas
0.35
0.35
Large
burner
Natural gas H
Liquid gas
0.50
0.50
Screw in the new jets according to the
following table.
Jet table
For UK and IE
Main jet
C
Small jet
C
Natural gas H
Medium burner
Large burner
1.00
1.28
0.42
0.52
Liquid gas
Medium burner
Large burner
0.67
0.87
0.27
0.32
The jet markings refer to 1/100 mm of
the jet diameter.
Conversion to another type of gas
51