Lopi Leyden Pellet Stove Stove User Manual


 
36 Maintenance
Travis Industries 4061016 100-01184
Yearly Maintenance (or every two tons) - continued
Clean the Exhaust Blower
The exhaust blower cover is held in place with 4 screws.
Remove the cover plate on the exhaust blower. Clean the area inside the blower, removing all flyash.
Flow Switch Tube
Nipple (attached to exhaust channel)
Remove the
side cover.
Remove these 3 nuts to
expose the exhaust blower.
Use the bottle brush to disoldge any
flyash near the exahust blower and in the
horizontal exhaust channel. Take care
to not damage the impeller on the
exhaust blower.
Check the nipple and flow switch tube. Insert a pipe
cleaner through the nipple to dislodge any flyash.
NOTE: The flow switch will shut off the auger if the
tube becomes clogged or dislodged. Make sure it is
cleaned out and correctly attached.