20 Operation
Travis Industries 4061016 100-01184
Safety Notice
Read this entire manual (especially the "Safety Precautions" on pages 4 and 5)
before using this stove. Failure to follow the instructions may result in property
damage, bodily injury, or even death.
! Do not unplug the stove to turn it off. This stove relies upon electricity to push the flue
gases out the pellet vent – unplugging it may lead to smoke entering your room.
! Failure to maintain your heater will lead to a restricted combustion air system, leading to
poor performance and in some cases, smoke spillage into the room. See the
"Maintenance" section for details.
Location of Controls
Control Panel
Thermostat or Remote
(required for Auto Operation)
Firepot
OFF
ROOM TEMP
°F
°F
SET TEMP
TIMER
MIN
Time
Set
Time
Cancel
A
u
t
o
Restrictor
The restrictor adjusts
the amount of air
flowing to the firepot.
Three tabs are provided on the
back of the stove to hang the
cleaning
tools (bend
the tabs out).
Starting the Heater for the First Time
Start the Heater - Let it Burn for 1 Hour - THEN OPEN THE DOOR
The stove paint is cured through heat. To prevent it from bonding to the door gasket, you must burn
the heater for approximately 1 hour, then open and close the door to break any bonding.
Curing the Paint
This stove uses a heat-activated paint that will
emit some fumes while starting the first fire.
Open doors and windows to the room to vent
these fumes. You may also notice oil burning
off of the interior of the stove. This rust-
stopping agent will soon dissipate.
Priming the Auger
2 to 4 hours
Because of its electronic control panel, this stove does not require priming. If you run out of pellets
you may notice it will take approximately 5 minutes longer for the stove to start.