Lopi Leyden Pellet Stove Stove User Manual


 
Installation (For Qualified Installers Only) 11
Travis Industries 4061016 100-01184
Mobile Home Requirements
Outside air is required (used for
combustion) - see the directions
below.
The heater must be bolted to the
floor (Some states do not require
this; check with your local building
department). See the illustration
to the right.
The heater must be grounded to
the steel chassis of the mobile
home (Some states do not require
this; check with your local building
department).
WARNING: DO NOT INSTALL IN
SLEEPING ROOM.
CAUTION: THE STRUCTURAL
INTEGRITY OF THE
MANUFACTURED HOME
FLOOR, WALL, AND
CEILING/ROOF MUST BE
MAINTAINED.
The leveling bolts in the legs may be used
in conjunction with the included clips (sku
210-03924) to secure the stove to the floor.
Outside Air (used for combustion)
Must not be drawn from an enclosed space (garage, unventilated crawl space).
HINT: Travis Industries strongly suggests outside air for all residential installations, especially for
those that are energy efficient, air-tight homes.
Must not be over 15' long (the kit includes a 4 length additional 3 diameter duct may be used).
Must be made with 3" diameter or larger metal or aluminum duct with a metal screen attached to
the end to keep out rodents (P.V.C. or other combustible materials may not be used). We
recommend the Travis Industries Outside Air Kit (part # 99200136).
Must not terminate above or within 1' of the chimney termination.
Must have a rain cap or down-turned elbow to prevent water from entering.
Must be located so that it will not become plugged by snow or other material.
3 Diameter Air Duct
A screen is required to prevent
rodents from entering.
Outside air entrance must be placed so it
does not become blocked by snow.
Air may be drawn from a ventilated crawl space.
Botttom of Stove
Use a hose clamp to secure the
aluminum air duct to the air inlet
flange on the stove.
Air Duct (3 Dia.)