Lodge Manufacturing GMD1-80N Furnace User Manual


 
All installations and services must be performed by qualified service personnel.
1
I. SAFETY SECTION
This page and the following two pages contain various warnings and cautions
found throughout this furnace Service and Installation Manual. Please read and
comply with the statements on the cover and the statements below.
: This furnace is not to be used as a construction heater.
: When testing electrical equipment, always follow standard electrical
procedures and precautions.
: The area around the furnace should be kept free and clear of
combustible materials, especially papers and rags.
: This furnace uses an automatic hot surface ignition control. NEVER
try to ignite gas manually.
: If the temperature rise exceeds 85°F, the heat exchanger may fail
voiding the heat exchanger warranty resulting in property damage, personal
injury or loss of life.
: Burner adjustments must be confirmed by instrumentation. Failure to
use accurate or calibrated instrumentation to setup the burner may result in
reduced efficiency, sooting, and/or the production of hazardous carbon
monoxide gas.
: Any attempt to relocate safety controls or replace safety controls with
a control that is not approved or incompatible, may result in personal injury,
substantial property damage or death.
: If you do not follow these instructions exactly, a fire or explosion may
result causing personal injury, loss of life or property damage.
: HAZARD OF ASPHYXIATION: Negative pressure inside the closet with
closet door closed and the furnace blower operating shall be no more negative
than minus 0.05 inch water column.
: Do not obstruct any return air openings, including the return grille on
the furnace. To do so may cause the furnace to activate the high limit and shut
down or it may cause asphyxiation.
: Because of the potential of odorant fade, a gas leak may not be
detected by smell. If this furnace is installed below grade, contact your gas
supplier for a gas detector.
: All gas pipe connections must be leak tested using a strong soap and
water solution (with the gas turned on). Any leaks must be repaired immediately