Lenoxx Electronics Optima 3 FS Stove User Manual


 
SPECIFICATIONS - Optima 2 FS
PAGE 34
Flue Size 3” / 76mm Rear
Width, Overall 23” / 584mm
Depth, Overall 22 3/4” / 578mm
Depth, Overall w / 3” tee 28 1/2” / 724mm
Height 28 5/8” / 727mm
Floor to Rear
Flue Center 11 1/4” / 286mm
Facing back of unit,
outside edge of left side
to center of rear
flue outlet center 6 1/2” / 165mm
Floor to Rear
Outside Air Inlet
Located on center-
line of pedestal back 5” / 127mm
Facing back of Unit
outside edge of right side
to center of air inlet 11 1/2” / 292mm
Floor Protection + Front and Sides: 6”/152mm
Requirements Back: Up to 6” / 152mm
Standard Features Fastfire Self Igniter
Wall Thermostat (wire in-
cluded)
Hopper Capacity 55 lbs.
Burn time 15-37 hours
Fuse, Control Board 5 Amp, 250 volt, 3AG *
Fuse, Igniter 6 Amp, 125 volt *
Heat Input (BTU’s per hour) 13,000-32,000 BTU / hr
Overall Efficiency 75-81%
Emissions 0.4 gr / hr (varies w/size
and type of fuel) EPA ex-
empt.
Shipping Weight 215 lbs.
Room Air Blower 150 CFM; .8 Amps,
2175 rpm
Auger Motor 1 RPM; .4 Amps
Exhaust Blower 95 CFM: 1.0 Amps,
2880 rpm
Fastfire Igniter 4.35 Amps,
Options Nickel or Gold Trim Kits
4” Quick Disconnect
Log Set
BACK VIEW
SIDE VIEW
Note: Dimensions shown are approximations only (+/- ¼”)
+ Non-combustible floor protection is required (see
Floor Protection, page 5). When installed at clear-
ances less than 6”, the floor protector is only re-
quired to extend to the wall.
Fuel delivery and burn times will vary depending
on size and type of fuel used. Estimated heat in-
put based on fuel value of 8400 BTU per lb.
* Fuses are rated as fast blow.
28 1/2"
w/clean-out tee
22 3/4"
23"
28 5/8"
11 ¼"
6 ½"
11 1/2"
8 ¾"
5 1/8"