Lenoxx Electronics Optima 3 FS Stove User Manual


 
ROUTINE MAINTENANCE
PAGE 31
Clean Photoeye Lens
Remove Filter and Wipe Clean
(Minimum frequency of 4 weeks - 6 months)
CAUTION: If the filter is not reinstalled, reflective
light in the room may result in a fault, thus shut-
ting down of the unit.
EXHAUST PASSAGES AND VENT PIPE (All Models)
Inspect frequently and clean when necessary. Fly ash will
accumulate at all bends in the exhaust system.
Note: Large amounts of fly ash build-up will create a lack
of combustion air. Removing the clean out tee cap on
vertical installations will allow an inspection of the ash
build-up in the clean out tee and will help you to decide
how frequently more extensive cleaning must be per-
formed.
Clean-Out Tee
* (Minimum Frequency of 1-2 months)
ASH CLEAN-OUT PORTS
Make sure stove is cold. Ash clean-out ports must be
cleaned as part of routine maintenance.
Accessing Clean-out Ports
Optima 3 Series (Firebrick panels must be removed
to access):
IMPORTANT: Clean-out cover plates must be in-
stalled when operating unit.
* (Minimum Frequency of 1-2 months)
Clean-Out Tee
Rain Cap
Remove cover, then
remove ash
REMOVE COVERS AND
VACUUM OUT FLYASH -
Loosen screws (1 pe
r
clean-out) and lift each
plate out. Use an ap-
proved ash vacuum o
r
brush to remove ash.
A
fter cleaning, replace
clean-out plates and
tighten screws.
Retainer Brackets
REMOVE RETAINER BRACKETS AND LIFT
FIREBRICK PANELS UP AND OUT – Using
a 5/16" nut driver, remove 2 screws in each
firebrick retainer bracket (located on the
sides of the inside firebox). Lift panels up
and out
.
Clean Photo-
Eye Lens
Filter