506052−01 11/09
Page 10
Installer setup − Page 5 of 8
Modify communicating device settings
Use this screen (figure 12) to access communicating devices’ settings.
Use back to return to the previous screen or next step to go on.
HP
XP19−060−230−06
5809K00015
AIR HANDLER
CBX32MV−60
5809K00020
THERMOSTAT
49W95
A109K00139
SYSTEM
setup HELP
about
next step
back
system devices
edit
reset ALL
to adjust a device, highlight
it, then press edit
Figure 12. Accessing communicating device settings
With one of the devices highlighted, press about, then use arrow keys to
see a list of data about the selected device. If you select reset ALL, and
then confirm, ALL devices will be reset to their factory settings. (You
would see a screen similar to figure 14.)
With one of the devices in figure 12 highlighted, press edit to go to that
device’s list of settings (see figure 13).
Use the up/down arrows to scroll through the device’s settings and ob-
serve the right hand side of the screen (figure 13) to see the current set-
ting, for example, Current Value: (Off). Press edit if you want to modify
that setting, or press back to return to the previous screen.
Equipment Name
Compressor Short
Cycle Delay
Defrost
Termination Temp
Compressor Shift
Delay On/Off
setup HELP
back
HP
edit
reset
to adjust a setting, highlight it,
then press edit
Current Value:
(Off)
Figure 13. Modify communicating device settings
Settings available for the devices are dependant on the components you
have. Shown below is an example of changing the compressor shift
delay on. After using the arrows to select On, press save to save the
changes and return to the previous screen.
save
cancel
On
Off
Compressor Shift Delay On/Off