Lennox Hearth ULC-S610 Indoor Fireplace User Manual


 
HOT AIR DUCTING INSTALLATION
The Montecito™ wood burning fireplace is
approved for use with a Gravity kit (hot air
ducting system).
Gravity Kit
The gravity kit is designed for double hot air
outlets and includes: (See Figure 14).
- Two(2)telescopiclengths8”I.D.
- Two(2)90ºelbows8”I.D.
- Two (2) hot air outlet kits
(grill and frames)
- Two (2) adaptors
See Gravity Kit Accessories Page 20.
For safe installation, the gravity kit must meet
the following requirements:
Minimum height*68”(1,727mm)
Maximum length See Figure 14
* The height of the louver must be measured
from the base of the Montecito fireplace to the
middle point of the louver.
The only blower that can be used with the gravity
kit is the one sold with the fireplace.
To extend the double outlet system, it will be
necessary to purchase two adjustable lengths
(7B26ZL2A).
Figure 15
When installing the double outlet system, the
hot air outlets can be installed in the same room
as the fireplace, or one or both of the outlets
can be installed in adjacent or upper rooms.
Installing the ducts at different elevations will
tend to exhaust more heat out of the higher
outlet (Figure 14).
Figure 14
Frame
Grill
Noncombustible Facing
Drywall
2” X 3” Min.
Rock Board or Other
Spacer
Figure 12
FIREPLACE BLOWER
The fireplace comes equipped with a heat acti-
vated blower. It is located in the bottom of the
fireplace, towards the back. It uses 120V and
must be connected to the main electrical circuit
by a qualified electrician. For connection, use the
electrical box supplied with the unit located on
the bottom right corner of the fireplace.
If you wish to adjust the blower speed, the
variablespeedcontrol(VRUW)providedmust
be installed in line with the wiring. Again, use
a qualified electrician for installation.
If the blower requires servicing,
1- Remove the doors and decorative facade.
2- Remove the screw located below the blower
motor that holds it to the back of fireplace.
3- Pull the blower out of the unit through the
square hole located in the front bottom right
corner.
Figure 13
Only non-combustible mate-
rial should be superposed or
projecting over the front of
the fireplace.
42”
(1067mm)
Min.
WARNING: Both pipes of
the double hot air outlet
must be installed. Any oth-
er installation may cause
fire and void warranty.
NOTE:DIAGRAMS&ILLUSTRATIONSARENOTTOSCALE.
10
13” x 13”
10’
(3.1m)
Max.
Maintain at least 6-1/2”
(160 mm) clearance from
the outlet grill framing to
a combustible ceiling,
side wall or mantel.
Outlet Grill
Outlet Grill
WARNING: The outlet grills
should not be installed fac-
ing upward through a floor.
Danger of burns can result
if grills in floor are stepped
on.
(330mm x 330mm)
10’ (3.1m)
Max.