Lennox Hearth LSM40ST-P Indoor Fireplace User Manual


 
8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 6: Optional Indoor Hearth Extension
Finish combustible material
must be installed at or below
base of fireplace.
Finish non-combustible material may
butt against front face of fireplace.
Also see Figure 7.
Floor
Panel
Front Face
of Fireplace
Figure 7: Optional Indoor and Outdoor Hearth Extensions
6" (152 mm)
minimum
Outdoor hearth extension:
All finish hearth material (combustible
and non-combustible) must be at least
6" (152 mm) below base of fireplace.
Outdoor
Side
Fireplace
(side view)
Indoor
Side
Indoor hearth extension:
Finish combustible material must be
installed at or below base of fireplace.
Finish non-combustible material may be
installed above base of fireplace and may
butt against front face of fireplace.
LENNOX HEARTH PRODUCTS • MONTEBELLO
®
SEE-THROUGH DIRECT-VENT GAS FIREPLACES (LSM40ST-N / LSM40ST-P) • INSTALLATION INSTRUCTIONS
Optional Indoor Hearth Extension
Combustible indoor hearth material may only be installed at or below
the base of the replace (see Figures 6 and 7).
Non-combustible indoor hearth material may be installed above the base
of the replace and may butt against the front face of the replace (see
Figures 6 and 7).
Also note the following:
Combustible material may project beyond the sides of the replace
opening, as long as it is within the shaded area shown in Figure 10
on Page 9.
Vertical installation clearances to combustible mantels vary according
to the depth of the mantel (see Figure 9 on Page 9).
Non-combustible mantels may be installed at any height above the
appliance opening.
Optional Outdoor Hearth Extension
All outdoor hearth material (combustible and non-combustible) must
be installed a minimum of 6" (152 mm) below the base of the replace
(see Figure 7).
Also note the following:
For vertical installation clearances to combustible outdoor mantels and
overhangs, see Page 32 and the instructions provided in the Outdoor
Installation Kit (required for all outdoor installations; see Page 34).
Non-combustible outdoor mantels and overhangs may be installed at
any height above the appliance opening.
HEARTH EXTENSIONS (OPTIONAL)
Note: Hearth extensions are not required with this appliance.