Lennox Hearth 30 FS-2 Stove User Manual


 
6
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
CLEARANCES - FREE-STANDING MODELS
Models: Profi le
®
20 FS-2 and Profi le 30 FS-2
Standard residential or manufactured home installation. These appliances
require the following minimum clearances to combustibles:
Figure 2 - Rear Wall or Alcove, Profi le
20 FS-2 and Profi le 30 FS-2
Combustible
Combustible
Combustible
Combustible
Combustible
Combustible
E
B
Profi le 20 FS-2
Horizontal Flue –
Directly Through Wall
Interior Vertical
Flue
A - Sidewall to unit 4” (102 mm) 4” (102 mm)
B - Backwall to unit * 2” (51 mm) 9” (229 mm)
C - Sidewall to unit Corner * 2” (51 mm) * 2” (51 mm)
D - Max. Depth of Alcove
24” (610 mm)
24” (610 mm)
E - Flue to Wall 3” (77 mm) 3” (77 mm)
Measured to fuel hopper lid in alcove.
Minimum Alcove Measurements - Height 48” (1220 mm) x Width 31”
(788 mm) x Maximum Depth 16” (406 mm)
Table 2 - Minimum Clearances To Combustibles
Profi le 30 FS-2
Horizontal Flue –
Directly Through Wall
Interior Vertical
Flue
A - Sidewall to unit 6” (153 mm) 6” (153 mm)
B - Backwall to unit * 2” (51 mm) 9” (229 mm)
C - Sidewall to unit Corner * 2” (51 mm) * 2” (51 mm)
D - Max. Depth of Alcove
16” (407 mm)
16” (407 mm)
E - Flue to Wall 3” (77 mm) 3” (77 mm)
Measured to fuel hopper lid in alcove.
Minimum Alcove Measurements - Height 48” (1220 mm) x Width 31”
(788 mm) x Maximum Depth 16” (406 mm)
Table 3 - Minimum Clearances To Combustibles
Combustible
A
A
D
E
C
C
E
C
C
Figure 3 - Corner, Profi le
20 FS-2
Figure 4 - Corner, Profi le
30 FS-2
IMPORTANT
Minimum clearances specifi ed may not allow
for ease of operation and maintenance (please
take this in to account when planning the instal-
lation). If installed to the minimum clearances,
removal of the appliance may be necessary for
servicing.
Recommended clearance zone from the front
of the appliance to combustibles is 4 feet mini-
mum.
The certifi ed back wall clearance as shown on the
listing label is 1” (see Safety / Listing Label) but
for proper hopper lid operation in corner and par-
allel installations a 2” clearance is required.