Lennox Hearth 30 FS-2 Stove User Manual


 
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
42
MANUFACTURED (MOBILE) HOME
OR RESIDENTIAL INSTALLATION
FREESTANDING STOVE
INSTALLATION
CAUTION:
HOT
SURFACES WHILE IN
OPERATION. DO NOT
TOUCH. CONTACT MAY
CAUSE SKIN BURNS.
KEEP CHILDREN, COMBUSTIBLE MA-
TERIAL AND FURNISHINGS A CONSID-
ERABLE DISTANCE AWAY. SEE
NAMEPLACE AND INSTRUCTIONS.
TYPE OF FUEL: PELLETIZED WOOD
FUEL ONLY.
INTERIOR
VERTICAL FLUE
INSTALLATION
HORIZONTAL FLUE-
DIRECTLY THROUGH WALL
INSTALLATION
MINIMUM CLEARANCES TO
COMBUSTIBLE MATERIALS
SIDEWALL TO UNIT *A* 4”/102 MM 4”/102 MM
BACKWALL TO UNIT B 1”/26 MM 9”/229 MM
WALL TO UNIT CORNER C 1”/26 MM 1”/26 MM
ALCOVE TO FUEL HOPPER D 4”/102 MM 4”/102 MM
MAX. DEPTH OF ALCOVE E 24”/610 MM 24”/610 MM
FLUE TO WALL
F 3”/77 MM 3”/77 MM
FRONT/REAR/SIDE TO FLOOR
PROTECTION OUTSIDE EDGE I 6”/153MM 6”/153 MM
CERTIFIED FOR U.S. AND CANADA. LISTED ROOM
HEATER FOR USE WITH APFI/FFI APPROVED
PELLETIZED WOOD FUEL ONLY. FOR USE IN
MANUFACTURED (MOBILE) HOMES, AND AS AN
INSERT FOR MASONRY AND FACTORY BUILT
FIREPLACES. MODEL: PROFILE 20-2 TESTED
TO ASTM E-1509 / UL 1482 / ULC-S627 /ULC-S628 REPORT NO. 6658
(JULY 1993).
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFAC-
TURER’S INSTALLATION INSTRUCTIONS. CONTACT LOCAL BUILDING
OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION IN-
SPECTION IN YOUR AREA. DO NOT CONNECT THIS UNIT TO A CHIM-
NEY FLUE SERVING ANOTHER APPLIANCE. SEE LOCAL BUILDING
CODE AND MANUFACTURER’S INSTRUCTIONS FOR PRECAUTIONS
REQUIRED FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE
WALL OR CEILING. THIS PELLET FIRED APPLIANCE HAS BEEN
TESTED AND LISTED FOR USE IN MANUFACTURED HOMES IN AC-
CORDANCE WITH OREGON ADMINISTRATIVE RULES 814-23-900
THROUGH 814-23-909.
OPERATE ONLY WITH FIREBRICK IN PLACE. WARNING: OPERATE
ONLY WITH VIEWING DOOR CLOSED. INSPECT FLUE FREQUENTLY
TO PREVENT ACCUMULATION OF SOOT. THE HEATER AND FLUE
MUST BE IN GOOD CONDITION. KEEP FURNISHINGS AND OTHER COM-
BUSTIBLE MATERIALS WELL AWAY FROM HEATER.
ROUTINE MAINTENANCE REMINDER
FREQUENCY OF CLEANING AND MAINTENANCE OF YOUR STOVE
DEPENDS ON THE ASH CONTENT OF THE PELLETS YOU BURN.
CHECK THE FOLLOWING PARTS OF YOUR STOVE WEEKLY FOR THE
FIRST MONTH TO DETERMINE THE FREQUENCY OF CLEANING.
A. BURN GRATE
B. HEAT EXCHANGER TUBES
C. ASH PAN AND EXHAUST PIPE
SEE YOUR MANUAL AND/OR DEALER FOR MORE INFORMATION.
INPUT RATING RANGE: 1.5 TO 3.8 LBS./HOUR (NOMINAL)
ELECTRICAL RATING: 60 HZ, 115 V, LESS THAN 10 AMP
DO NOT REMOVE THIS LABEL
F
B
A
BACK WALL
E
D
D
B
ALCOVE BACK WALL
W T
N
ECA
JD
A
L
LA
F
C
C
COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUS-
TIBLE MATERIAL EXTENDING BENEATH THE HEATER AND 6” TO
THE FRONT, SIDES AND REAR AS INDICATED OR TO THE NEAREST
PERMITTED COMBUSTIBLE MATERIAL.
USE 3” / 75mm or 4” / 100mm Type “PL” LISTED PELLET VENT AND
COMPLETE COMPONENTS.
INSERT MODEL
MAY BE INSTALLED IN A MASONRY FIREPLACE THAT MEETS
NATIONAL AND LOCAL BUILDING CODE REQUIREMENTS (UBC
37 OR ULC S628). DO NOT REMOVE BRICKS OR MORTAR. MAY
BE INSTALLED IN A FACTORY BUILT (“ZERO CLEARANCE”)
FIREPLACE (UL 127 OR ULC S610). DO NOT ALTER OR MODIFY
THE FIREPLACE STRUCTURE. REFER TO OWNER’S MANUAL
FOR SPECIFIC INSTALLATION REQUIREMENTS.
*60020146 REV E*
WH-