Lennox Hearth 30 FS-2 Stove User Manual


 
44
CASCADE
Select Your Installation Type
VENTING TYPE
a:
PL-Vent Pipe / Pellet Vent (w/stainless interliner)
b:
Stainless Steel flex liner may be used inside
existing flue or chimney (fireplace insert
or woodstove replacement applications )
CAUTION: Do not use Type B-Vent Pipe
GOOD INSTALLATION:
Horizontal Installation
(Direct Vent - Outside Wall)
BETTER INSTALLATION:
Vertical & Horizontal Installation
(Up and Out)
Caution: Appliance/stove may not be installed
in location facing direct sunlight (not applicable to Advantage II-T C & Cascade).
BEST INSTALLATION:
Vertical Installation
(Straight Up)
REQUIRES 3" DIAMETER STANDARD
PL-VENT / PELLET PIPE
With listed termination kit.
If installation requires in excess of 11' of pipe, it is
recommended a 4" diameter pipe be used.
MANUFACTURED HOME
Requires outside air for
combustion. Use a galvanized
or stainless steel pipe for duct.
Minimum duct size 1 5/8" dia.
CLEARANCES TO COMBUSTIBLES
Ensure all clearances are maintained in
accordance to instructions contained on
product safety label and in compliance
with pipe/venting requirements.
Note: Leave sufficient clearance
for routine cleaning and maintenance.
Seal all Venting Joints: Use
RTV (high temp silicone)
POWER SUPPLY
Must have proper polarity &
be grounded.
Note: Use of an extension
cord may adversely effect
the performance of your unit.
Please Review "Installation
and Operation" Manual for
Additional Instructions.
Pellet
Stove
Models:
INSTALLATION TIPS
No natural draft. Wind pressures
may affect operation
Some natural draft aids venting.
Wind pressures may still affect operation
Natural draft improves operation and
negative effects from wind
ADVANTAGE OPTIMA & PROFILE SERIES
ADVANTAGE II-T C
P/N 60020242, REV. NC
T300P-2 SERIES
INSTALLATION TIPS