Kramer Electronics VP-719DS Vacuum Cleaner User Manual


 
P/N: 2900-0070144 A1
Addendum: Scalers Group
Additional Features of the Scaler Products Group according to
the Master-Firmware Ver-2.33 Release.
1. This version requires Slave Firmware version 1.06 or higher. The version can be
seen in the INFO section of the on-screen menu. Contact your Kramer service center if
you have any questions.
2. Improved functionality lets you select the PIP source via the RS-232
command. Sending an inappropriate PIP source command (request video PIP source
while the main video input is selected; or the same for graphic sources) will not cause
the unit to operate erroneously. In such a case, the unit will ignore the command and
return the message: “ineffective source”. This option does not apply to the VP-719DS.
3. Added PIP position(s) commands in the RS-232 protocol. These commands
let you input the absolute value (from 0 to 36) of the horizontal and vertical positions of
the PIP. For details, see the protocol table. This option does not apply to the VP-719DS.
4. Added new output resolution 1280x768. This resolution is marked with an
asterisk “*” to attract your attention to the fact that this is not a standard VESA
resolution and its parameters vary from manufacturer to manufacturer. Therefore, this
resolution must be used with caution. It is also possible to use the parameters of this
resolution in combination with the User Defined resolution (see below). There is also an
RS-232 command for this resolution. For details, see the protocol table.
5. Added 50 Hz output refresh rate. This is for special cases only. Many of the
modern screens and projectors have difficulties working with such a low frequency.
6. In the OSD under UTILITIES>ADVANCED there is new item: “Input
Button”. This item defines an action after repeatedly pressing the same input selection
button. This item has following options:
 FREEZE/BLANK – this is the current situation (quoting from the user
manual: Press again (when the LED illuminates) to freeze the image; the LED
flashes. Press once again (when the LED flashes), to display a blank screen; the
LED flashes more slowly)). This remains the factory default
 FREEZE – pressing the button toggles between LIVE and FREEZE
 BLANK – pressing the button toggles between LIVE and BLANK
 IGNORE – after selecting the source, the button is ignored
The settings also apply to the input buttons on the IR control.
7. Under the Utility>PIP Setting there is new item: “PIP Frame”. This feature
allows the enable/disable yellow frame around the PIP through the OSD or the new
RS-232 command: L 50AF. The RS-232 command allows PIP frame enable/disable
while the PIP is activated. However, before doing it via the OSD you must switch the
PIP OFF. While the frame is activated, pressing the UP and DOWN buttons on the front
panel and on the IR remote control would toggle through the PIP size settings. This
option does not apply to the VP-719DS.