Kohler Discovery Plumbing Product User Manual


 
6
SPECIFICATIONS
Pressures
Maximum Static Pressure: 10 Bar.
Minimum Maintained Pressure (Gas Water Heater): 1.0 Bar.
(for optimum performance initial supplies should be nominally equal).
Minimum Maintained Pressure (Gravity System): 0.1 Bar.
(0.1 bar = 1 Metre head from base of cold tank to the outlet of the shower handset).
Maximum Maintained Pressure: 5 Bar.
Temperatures
Factory Pre-set (Blend) Shower: 43°C.
Optimum Thermostatic Control Range: 35°C - 45°C.
(Achieved with supplies of 15°C cold, 65°C hot and nominally equal pressures).
Max. Hot Supply: 85°C.
Recommended Hot Supply: 60°C - 65°C.
Min. Differential between Hot Supply and Outlet Temperature: 10°C.
Cold Water Range: 1°C - 20°C.
Flow Rates
Typical Flow Rates - Mira Discovery Dual Control with Adjustable Fittings:
Start (Outer Spray)
Soothe (Middle Spray)
Force (Inner Spray)
Rigid (Fixed Spray)
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
0
2
4
6
8
10
12
14
16
18
Supply Pressure (Bar)
Flow Rate (L/Min)
With 12 L/Min Flow
Regulator Fitted