14
1.14Re-fit the building-in shroud to the shower valve using the three fixing screws.
1.15Using the building-in shroud as a guide for the finished wall thickness, finish the
wall.
Caution! Make sure that the finished wall is within the minimum and maximum
limits otherwise the control components will not fit correctly.
1.16Remove the building-in shroud. Retain the three securing screws for securing the
backplate.
1.17Fit the shower fittings, refer to your fittings installation and user guide for
instructions.
1.18Fit the control assembly, refer to section: ‘Control Assembly’.
Securing
Screws
Building-in
Shroud
Spirit Level
Maximum
Building-in Depth
Minimum
Building-in Depth