Kohler CFI230J Plumbing Product User Manual


 
14
CFI230J
15
CFI230J
COMMISSIONING/SETTING
1. General
1.1. Turn on the water supply to the Digital Mixer.
1.2. Check for leaks over the complete system.
1.3. Turn on the electrical supply to the Digital Mixer.
For the Pumped Version with the Slide Rail System, pump priming can be helped by removing the handset
and lowering the end of the hose into the shower tray.
2. Set the Maximum Temperature
Note! The maximum temperature of the unit can only be set when the unit has not been used for a period of
10 minutes or after switching the unit’s electrical supply OFF and ON.
2.1. Temperature Selection - Set the temperature control knob to the desired position, as per the table
below.
2.2. Enabling - Press and momentarily hold the Warm Up/Stop and High push-buttons at the same time.
Release the push-buttons and press them again within 2 seconds. The High push-button will flash and beep
three times to confirm the selection is successful.
3. Lock Mode
Note! Allows you to lock the unit during operation.
3.1. There are two Safety Lock Modes
Option 1 - Locks the mixer to your flow and temperature settings.
Option 2 - Locks the interface so no push-buttons can be used.
Note! The Warm Up/Stop push-button will be illuminated on the interface used to set the lock mode, no
other interface will be illuminated.
Temperature Control Temperature Selection °C
Knob Position
1 Factory Set 45°C
2 45°C
3 36°C
4 38°C
5 40°C
6 42°C
7 45°C
8 47°C
9 48°C
Setting Option 1
Operate the shower and set the desired flow and temperature, then press and momentarily hold the
Warm Up/Stop and Medium push-buttons at the same time. The Medium push-button will flash and
beep three times to confirm the selection is successful.
The mixer is locked to your selected temperature and flow. Pressing any flow push-button turns the
mixer ON. Pressing the Warm Up/Stop push-button turns the mixer OFF.
Caution! If the temperature control knob is altered while the mixer is in standby mode or while
the shower is in operation, the water temperature settings will be changed to the new setting next time
the shower is used.
Note! Selecting the Warm Up/Stop and Medium push-buttons at the same time again, cancels the
lock mode option set. The Medium push-button will flash and beep three times
Setting Otion 2
Note! This can only be set when the mixer has not been used for a period of 10 minutes. Switching the
unit’s electrical supply OFF and ON cancels the lock mode.
Press and momentarily hold the Warm Up/Stop and Medium push-buttons at the same time. The
Medium push-button will flash and beep three times to confirm the selection is successful. The
interfaces are locked.
Note! Selecting the Warm Up/Stop and Medium push-buttons at the same time again, cancels the
lock mode option set. The Medium push-button will flash and beep three times
4. Timeout
Note! Timeout allows you to run the shower for a set period of time before it automatically shuts off. This can
only be set when the unit has not been used for a period of 30 minutes or after switching the unit‘s electrical
supply OFF and ON.
4.1. Timeout Selection - Set the temperature control knob to the desired position, as per the table below.
4.2. Enabling - Press and momentarily hold the Warm Up/Stop and Low push-buttons at the same
time. The Low push-button will flash and beep three times to confirm the selection is successful.
Temperature Control Timeout (Minutes)
Knob Position
1 30
2 30
3 3
4 4
5 5
6 6
7 7
8 8
9 9