Kenmore 78122 Air Conditioner User Manual


 
INSTALLATION REQUIREMENTS
Your air conditioner willinstall into standard double
hung windows with actual clear opening widths of
27 to 39 inches (686mm to 990mm) (FIG. 1).
Lower sash must open sufficiently to allow a clear
vertical opening of 16 inches (406mm). Side louvers
and the rear of the air conditioner must have clear
air space to allow enough airflow through the
condenser for heat removal. The rear of the unit
must be outdoors, not inside a building or garage.
27" to 39"_
min __
Interior wall
Offset
_;_, Sill
I_ Exterior
....... FIG. 1
ELECTRICAL SERVICE
Check your available electrical service. The power
supply available must be the same as that shown
on the unit nameplate (foundon rightside of cabinet).
All models are equipped with a 3-prong service plug
to provide proper service and safe positive
grounding. Do not change plug in any way. Do not
use an adapter plug. If your present wall outlet does
not match your plug, call a qualified electrician to
make the necessary corrections.
SAVE CARTON and this OWNER'S MANUAL for
future reference. The carton isthe best way to store
unit during winter or when not in use.
INSTALLATION HARDWARE
P
FIG. 2
NO.
1
2
3
4
5
6
7
8
9
10
11
12
NAME OF PARTS
SIDE CURTAIN
SILL SUPPORT
BOLT
NUT
SCREW(TYPE A): 25/64"
SCREW(TYPE B): 5/8"
SCREW(TYPE C): 5/8"
FOAM SEAL
UPPER GUIDE
FOAM-PE
FOAM-PE
WINDOW LOCKINGBRACKET
Q'TY
2
2
2
2
16
3
5
1
1
1
1
1
To avoid riskof personal injury, propedy damage,
or product damage due to the weight of this device
and sharp edges that may be exposed:
Air conditioners covered in this manual pose an
excessive weight hazard. Two or more people are
needed to move and install the unit.
To prevent injury or strain, use proper lifting and
carrying techniques when moving unit.
Carefully inspect location where air conditioner
will be installed.
Be sure it will supportthe weight of the unit over
an extended pedor of time.
Handle air conditioner with care. Wear protective
gloves whenever liftingor carrying the unit.
AVOID the sharp metal fins of front and rear coils.
Make sure air conditioner does not fall during
installation.
REQUIRED TOOLS:
Tight Fitting gloves Pliers 3/8-inch open end wrench Tape measure
Standard screwdriver Sharp knife oradjustablewrench Electricdrill
Phillips screwdriver Carpenters level andl/4"inChratcherheXsocket 1/4-inch drille bit
-5-