See the chart below for wiring and outlet information.
OBSERVE ALL LOCAL GOVERNING CODES AND ORDINANCES
Never remove the power supply cord ground prong.
For 115 volt models with
nameplate amps up to
and including 12.0
For 115 volt models with
nameplate amps of 12.1
through 16.0
PLUG AND
RECEPTACLE
DATA
PARALLEL
SRECEPTACLE
CATNO 34A5925
F_GpL_T BLADE
GROUND
RO.Sk%l
'T" BLADE ]
RECEPTACk_
CATNO 34-5242
RECEPTACLE
VOLTAGE
(60HERTZ
AC IN ALL
INSTANCES)
115
115
NAMEPLATE
AMPERES
Up
through
12.6
12.1
through
16.0
USE TIME-
DELAY FUSE
OR CIRCUIT
BREAKER
RATING IN
AMPS
15
2O
MINIMUM
RECEPTACLE
WIRE SIZE
14GAUGE
USE COPPER
WIRE ONLY
12GAUGE
USECOPPER
WIRE ONLY
TYPE OR
BRANCH
CIRCUIT
SINGLE
OUTLET
ONLY
SINGLE
OUTLET
ONLY
This unit requires a three-wire, single-phase, 60 hertz, AC only electrical supply.
Receptacle wire must be at least as large as size shown on electrical chad.
For your personal safety, this appliance must be grounded. This appliance has a power supply cord with a
3-prong grounding plug.
PROPER HOUSE WIRING
Follow all of the enclosed instructionscarefully for trouble-free performance and lowest operating costs.
USE ONLY TIME-DELAY FUSE (or circuit breaker) for safe use and to help prevent needless blowing of
fuses.
PROPER SIZE OF HOUSEWIRING is needed for good voltage and to keep from ovedoading circuit. See
data on reverse side. Avoid long lengths of housewiringthat can cause the voltage to drop below the
voltage shown on the nameplate.
It is best that NO OTHER APPLIANCE or devices are on the same fused circuitto which this unit is
connected. A blown fuse can result from wiring that is carrying more electrical current than it can safety
handle.
DANGER: DO NOT USE AN EXTENSION CORD.
The power cord with the air conditioner is the best size for safe and efficient use of your air conditioner. Use
of an extension cord may cause overheating, energy loss, and blown fuses or circuit breakers.
UNLESS THE PRODUCT IS GROUNDED PROPERLY, YOU ARE NOT PROTECTED AGAINST SEVERE
OR LETHAL SHOCK IN THE EVENT OF A SHORT CIRCUIT OF AN ELECTRICAL PART OR
THE WIRING OF THE AIR CONDITIONER.
-4-