Kenmore 625.348670 Water System User Manual


 
HOW YOUR WATER SOFTENER WORKS
SECTION 2
11
2A. FACEPLATE TIMER FEATURES
OPTIONAL ADJUSTABLE SETTINGS
Following is a list of other timer features that are
adjustable, and the default setting for each. The
defaults automatically set when electrical power is
applied to the timer. If you want to change from any
of thedefault values, scroll through steps 1 - 5 below,
and reset as desired.
1.Press andholdthe #1SELECT buttonfor 3seconds
until the faceplate display changes. Then, press and
release the #1 SELECT button to display 12 hr.
"12 or 24 Hour clock - defaults to 12 hr: At the 12
hr default setting, all time displays are shown in
standard clock time (1 to 12 PM; and 1 to 12 AM). If
military time displays are desired (0100, 0200, etc.),
set to 24 hr by pressing the UP button.
8
7
6
5
4
3
2
1
SALT
LEVEL
SIGNAL
LEVEL
8
7
6
5
4
3
2
1
SALT
LEVEL
SIGNAL
LEVEL
TIME TIME
AM
PM
2. Press #1 SELECT BUTTON
" Gallon or Liter readings - defaults to gallons:
Water usage and flow displays are shown in gallons.
If you prefer tohave the same displays in liters, press
the UP button until Liter shows.
8
7
6
5
4
3
2
1
SALT
LEVEL
SIGNAL
LEVEL
8
7
6
5
4
3
2
1
SALT
LEVEL
SIGNAL
LEVEL
GALLONS
LITERS
3. Press #1 SELECT BUTTON
" Maximum Days Between Regenerations -
default is zero days: The faceplate timer automati-
cally controls regeneration frequency (see page
14). Thisprovides the greatest operating efficiency,
and normally the maximum days feature is not
needed. If you want to be certain a regeneration will
occur within a number of days, use this feature. For
example, if your water supply contains iron and you
wantthe softenerto regenerateat least once everyfew
days to keep the resin bed clean, set the display as
typically shown below. Setting is available from 1 to
15 days by using the UP and DOWN buttons.
NOTE:
Setting a number in this display may override the
function of the water meter and timer computer (see
page 15). For example, assume the meter/computer
would initiate softener regenerations every 6 or 7
days. If you have max days set to 4, as shown below,
regenerations will occur every 4 days instead of
every 6 or 7.
8
7
6
5
4
3
2
1
SALT
LEVEL
SIGNAL
LEVEL
8
7
6
5
4
3
2
1
SALT
LEVEL
SIGNAL
LEVEL
RECHARGE
DAY
default display
example: set to
4 days maxi-
mum between
regenerations
RECHARGE
DAY
4. Press #1 SELECT BUTTON
" CLEANfeature minutes - default is 7 minutes:
If you have set this feature to ON (page7), the length
of the extra backwash cycle automatically sets to 7
minutes. However, you canadjust this time from 1 to
15 minutes in length. If you have a minimum of iron
or sediments, a 3 or 4 minute clean cycle may be
enough to keep the resin bed clean. If you have a
higher amount of iron or sediments, a setting of over
7 minutes may be needed. To change this cycle time,
use the UP buttonto increase the time, or the DOWN
button to shorten the time.
8
7
6
5
4
3
2
1
SALT
LEVEL
SIGNAL
LEVEL
8
7
6
5
4
3
2
1
SALT
LEVEL
SIGNAL
LEVEL
CLEAN
TIME
MIN
CLEAN
TIME
MIN
default minutes example: time set to 3 minutes
5. Press #1 SELECT to return the present time
display.