SECTION 1 WATER SOFTENER START-UP
1C. PROGRAM THE TIMER
2. SET WATER HARDNESS
Press the SELECT button
(flashing) and HARDNESS.
The grains per gallon (gpg)
hardness of your water supply
is on your water analysis re-
port. Be sure to enter water test
results on page 2, for future
reference.
NUMBER:
once to display 25
HARDNESS
NOTE:
If your water supply contains iron, compensate for
it by adding to the water hardness number. For
example, ass ume your water is 20 gpg hard and con tains
2 ppm iron. Add 5 to the hardness number for each 1
ppm of iron. In this example, you would use 30for your
hardness n umber.
20 gpg hardness
2ppmironx5=10 +10
(times) 30 HARDNESS NUMBER
Press the UP / DOWN buttons to set your water
hardness number in the display. The DOWN
button moves the display to 1. The UP button
moves the display to the highest setting (see
maximum setting for your model in the specifica-
tions).
NOTE:
Each press of the UP / DOWN button changes the
display by I between I and 25. Between 25 and the
highest number, the display changes 5 at a
time...25, 30, 35, etc. Holding the UP or DOWN
button in changes the display twice each second.
3. SET RECHARGE (REGENERATION) TIME:
Press the SELECT button to display 2:00 AM
(flashing) and RECHARGE TIME.
At the 2:00 AM recharge time q,nnA_
I_-'UU
setting, the softener begins re- RECHAROE
TIME
generation (see pages 12 and
13) at 2:00 AM, ending no later
than 4:00 AM. This is a good time in most
households because water is not being used (see
Automatic Bypass, page 14). If a different recharge
time setting would be better for your household,
do the following.
Press the UP / DOWN buttons to set the desired
recharge starting hour. Be sure to observe the
AM-PM as you did when setting the present time
of day.
NOTE:
Each press of the UP / DOWN buttons changes the
display i hour. Holding the buttons in changes the
display twice each second.
4. SET CLEAN FEATURE (optional):
Press the SELECT button to display OFF
(flashing) and CLEAN.
This feature is beneficial on nrr
water supplies containing iron ur r-
and/or high amounts of sedi- CLEAN
ments (sand, silt, dirt, etc.).
When set to ON, a backwash n I
and fast rinse cycle will occur Ur-
CLEAN
first, preceeding the normal re-
generation sequence (see page
12). This provides extra clean-
ing of the resin bed before it is
regenerated with the salt brine. To conserve water,
if your water supply does not contain iron or
sediments, be sure this feature is set to OFF. Use the
UP / Down buttons to change the ON / OFF
displays.
Press the SELECT button once again, to return
the present time, and RECHARGE TONIGHT in the
display.
5 RECHARGE TO_iGR?
4 WAI_HPLOW
3
2
1
IF YOU NEED HELP PROGRAMMING THE TIMER, CALL TOLL FREE, NUMBER
1-800-426-9345. SEE PAGES 10 AND 11 FOR OTHER FACE PLATE TIMER FEATURES.
7