Kenmore 625.3486 Water System User Manual


 
SECTION 4 OTHER THINGS TO KNOW
I I
4A. DIMENSIONS/SPECIFICATIONS
BYPASS VALVES
Bypass valve(s) should always remain in soft
water service position. Position in "bypass"
only if needed for softener repairs.
SINGLE
PULL OUT
for service
_PUSH IN
for bypass
3 - VALVE
FOR SERVICE
close bypass valve
open inlet & outlet valves
FOR BYPASS
open bypass valve
close inlet & outlet valves
Outlet
Valve
Bypass
Valve
A
II
B--_
\ /
-,_, ,r/
D
C
T
INCHES CM
A Salt Tank Height 40-1/4 102.2
B Resin Tank Diameter (nominal) 9 22.7
C Resin Tank Height (nominal) 40 101.6
D Inlet-Outlet Height 41-1/2 105.4
E Overall Height 47 119.4
F1 Length 19-1/2 49.5
F2 Width 16-1/2 41.9
-- Distance between inlet-outlet 3-7/8 9.8
center lines
MODEL NO. 625.348600 TIMER HF CODE HF31
NOTE: Please see the rating decal for water softener operating capacity, salt usage and service flow rate/
pressure loss performance specifications. Performance specifications are validated by the Water Quality
Association (WQA). The rating decal is located on the rim, under the salt hole cover (see page 28).
WATER SUPPLY TO WATER SOFTENER
MINIMUM WATER SYSTEM FLOW (gpm) ................ 3
MINIMUM-MAXIMUM WATER PRESSURE (psi) ...... 20-120
MAXIMUM WATER TEMPERATURE (°F) ............... 120
MAXIMUM WATER HARDNESS (gpg) .................. 110
MAXMUM "CLEAR WATER" IRON (ppm) ................. 7
SALT FOR WATER SOFTENER
TYPE OF SALT NEEDED .................... Nugget/Pellet
ALTERNATE TYPE OF SALT .. Pure, evaporated, compacted
water softener salt
STORAGE CAPACITY (pounds) ....................... 200
OTHERS
TYPE OF ION EXCHANGE MATERIAL (resin) High Capacity
AMOUNT OF RESIN (cu.ft.) ........................... 1.0
REGENERATION (RECHARGE) CYCLE TIME (min.)
FILL ......................................... 3 - 13
BRINING / BR. RINSE ............................. 120
BACKWASH ....................................... 7
FAST RINSE ....................................... 3
TOTAL REGENERATION TIME _ ............. 133 - 143
gpm = gallons per minute psi = pounds per square inch
gpg = grains per gallon ppm = parts per million
Does not include CLEAN feature cycle times if set to ON.